Regency P48-2 User Manual

Page of 52
Regency
®
 P48-2 Zero Clearance Direct Vent Gas Fireplace
45
MAINTENANCE
6)  Remove the burner by removing the screw 
on the left side and then slide the burner to 
the left and lift out.
7)  Remove the right and left side defl ectors by 
removing the 2 screws on each defl ector.
REMOVING VALVE
1)  Shut off the gas supply.
2)  Remove the louvers (and bay door if it has 
been installed).
3)  Open the fl ush door and remove the door.
4)  Remove the logs and side brick panels, if 
installed.
5)  Remove the grate by lifting up and out.
8)  Remove the base brick panels.
9)  Disconnect the inlet gas line. 
10) Remove the 10 Phillips head screws securing 
the valve tray assembly in place and then 
lift the entire assembly out.
Slide the burner to the left and lift out.
Grate
Remove the screw on the left
side of the burner.
Right Side 
Defl ector
Left Side 
Defl ector
11) Disconnect the 2 TP wires and the 2 TH 
wires from the valve.
12) Undo the pilot tube from the valve with a 
7/16" wrench.
13) Undo the quick drop out thermocouple nut 
on the valve with a 9mm (metric) wrench.
14) Remove the Piezo igniter wire and push 
button assembly.  
Valve Tray
Assembly
Lift entire valve tray 
assembly out.
15) Undo the "gas out" fl are nut with a 13/16" 
wrench.
16) Undo the "gas out" fl are fi tting with an 11/16" 
wrench.
17) Remove the 4 Phillips head screws from 
the sides of the valve bracket and remove 
valve.
Hint: 
If you are using black pipe, ensure 
that there is a union by the valve, 
otherwise removal will be almost 
impossible.
Thermopile
Wire
Thermocouple
Wire
Pilot Nut