U35 FPI Direct Vent Gas Insert
Use the FPI Remote Control Kit approved for 
this unit. Use of other systems may void your 
warranty.
The remote control kit comes with a hand held 
transmitter, a receiver and a wall mounting 
plate.
1)  Choose a convenient location on the wall 
to install the receiver and the receptacle 
box (protection from extreme heat is very 
important). Run wires from the fi replace to 
that location. Use Thermostat Wire Table.
2)  Connect the wires as per the wiring diagrams 
below.
CAUTION
Do not connect the millivolt 
remote control wires
to the 120V wires.
3)  Install 3 AAA alkaline batteries in transmitter 
and 4 AA alkaline batteries in  the receiver. 
Install the receiver and its cover in the wall. 
Switch the  remote receiver to "remote" 
mode. The remote control is now ready for 
operation.
OPTIONAL REMOTE CONTROL 
OPTIONAL WALL 
THERMOSTAT 
A wall thermostat may be installed if desired, 
follow the wiring diagram below. Note: the wires 
are connected to the "TH" on the gas valve. Use 
the table below to determine the maximum wire 
length. FPI offers an optional programmable 
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or 
UL approved may be used.
It is recommended that the thermostat be 
installed on an interior wall.
CAUTION
Do not connect the millivolt 
wall thermostat wires
to the 120V wires.
INSTALLATION 
For 
PROPANE
 Units and Units Equipped with DC Spark Boxes