Regency P121 User Manual

Page of 48
Regency
®
 P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace
37
12) Lift the entire assembly out.
8)  Remove  the Side Base Brick Panels and 
fi nally the Long Base Brick Panels.
MAINTENANCE
Remove Left & Right  Side Base 
Brick Panels
Remove the 2 Long Base Brick Panels
9)  Disconnect the inlet gas line.
10) Disconnect the 2 TP wires and the 2 TH 
wires from the valve.
11) Remove the 16 Phillips head screws 
securing the valve tray.
13) Undo the pilot tube from the valve with a 
 7/16" 
wrench.
14) Undo the quick drop out thermocouple nut 
on the valve with a 9mm (metric) wrench.
15) Remove the Piezo igniter wire and push 
button assembly.  
16) Undo the "gas out" fl are nut with a 13/16" 
wrench.
17) Undo the "gas out" fl are fi tting with an 
 11/16" 
wrench.
18) Remove the 6 Phillips head screws from 
the sides of the valve bracket and remove 
valve.
Hint: 
If you are using black pipe, ensure 
that there is a union by the valve, 
otherwise removal will be almost 
impossible.
REMOVING VALVE
1)  Shut off the gas supply.
2)  Remove the louvers and trim kit. Remove 
the front door.
3)  Remove the logs, embers.
4)  Remove the grate by lifting straight up. 
7)  Slide the burner assembly away from the 
orifi ce and lift out.
5)  Remove the side brick clip in the top of the 
fi rebox and then slide the Side Brick Panel 
out.  The brick panels are very  fragile 
- handle with care.
6)  Remove the burner by removing the 4 
screws.