 P40 Direct Vent Gas Fireplace
24
INST
ALLA
TION
P40-NG SYSTEM DATA 
For 0 to 4500 feet altitude
Front Burner Orifi ce: 
#44
Back Burner Orifi ce: 
#35
 
 
                  
Max. Input Rating  45,000 
Btu/h 
Min. Input Rating 
13,000 Btu/h 
 
Supply Pressure min.5.0" 
w.c.
 
 
 
Manifold Pressure  
 (High)
 3.5"+/- 
0.3"w.c.
Log Set: Ceramic fi bre,
 
       8 per set + ember bed.
Vent System:  Simpson Dura-Vent Direct 
Vent System, Regency
®
 Flex Kit, Selkirk 
Direct-Temp
 
P40-LP SYSTEM DATA 
Conversion Kit# 502-969
For 0 to 4500 feet altitude
Front Burner Orifi ce: 
#55
Back Burner Orifi ce: 
#53
 
                 
Max. Input Rating 
43,000 Btu/h
Min. Input Rating 
12,000 Btu/h
Supply Pressure min.12.0" 
w.c.
Manifold Pressure  
 (High)
  
10"+/- 0.5" w.c.
Log Set: Ceramic fi bre,
 
       8 per set + ember bed.
Vent System:  Simpson Dura-Vent Direct 
Vent System, Regency
®
 Flex Kit, Selkirk 
Direct-Temp
Periodically check the pilot fl ames. Correct 
fl ame pattern has three strong blue fl ames: 
1 fl owing around the thermopile, 1 around 
the thermocouple and 1 fl owing across the 
burner (it does not have to be touching the 
burner).
Note:  If you have an incorrect fl ame pattern, 
contact your Regency
®
 dealer for 
further instructions.
Incorrect fl ame pattern will have small, 
probably yellow fl ames, not coming into 
proper contact with the rear burner or 
thermopile or thermocouple. 
 
PILOT ADJUSTMENT
INSTALLATION
GAS LINE 
INSTALLATION
The gas line can be brought through the bottom 
right of the appliance. The gas valve is situated 
on the bottom of the unit.
The gas line connection may be made of rigid 
pipe, copper pipe or an approved fl ex connector. 
(If you are using rigid pipe, ensure that the valve 
can be removed for servicing.) Since some 
municipalities have additional local codes it is 
always best to consult with your local authorities 
and the CAN/CGA B149 installation code.
For USA installations follow local codes and/or the 
current National Fuel Gas Code, ANSI Z223.1.
HIGH ELEVATION
This unit is approved in Canada for altitude 0 to 
4500 ft. (CAN1 2.17-M91).
When using copper or fl ex connectors use only 
approved fi ttings. Always provide a union so 
that gas lines can be easily disconnected for 
servicing. Flare nuts for copper lines and fl ex 
connectors are usually considered to meet this 
requirement.
IMPORTANT: Always check for gas leaks 
with a soap and water solution or gas leak 
detector. Do not use open fl ame for leak 
testing.