Regency FP90 User Manual

Page of 40
FPI FP90 Wood Fireplace
20
INST
ALLA
TION
Side 
Panel
Top
Panel
Insulation
Top
Brick
Bottom
Vermiculite
MASONRY LINER / 
BRICKS
Insulated refractory panels are included to 
extend the life of the fi replace and help radiate 
heat more evenly.  Make sure Insulating Paper 
is in place along the bottom, side and rear before 
bricks are put into place.  
Using the diagram to fi nd the correct location 
of the panels install in the following sequence:  
rear, sides, bottom, top. Care should be taken 
not to damage the panels during installation. THE 
ANDIRONS SHOULD NOT BE REMOVED.
SECONDARY AIR TUBE 
INSTALLATION 
1)   Slide air tube into the hole on the left hand 
side of the fi rebox as far as it will go.  The 
notch in the air tube should be facing the 
right hand side of the fi rebox.
2)  Slide the air tube back towards the right side 
until it locks into place. To lock into position, 
use a pair of vise grips and tap them with a 
mallet until the tube locks into place. The air 
holes should be pointing down toward the 
primary air opening just inside the bottom 
of the door opening.  The air tube will be 
diffi cult to snap into place because it has 
to be a snug fi t in order to prevent it from 
falling out when a fi re is burning.
GLASS
INSTALLATION
Remove the wire retainer from the doors, and 
place the glass in the doors, making sure that 
the glass gasketing will properly seal your unit.  
The retainer should be resting on the gasketing 
not on the glass. Tighten securely, but do not 
wrench down on the glass as this may cause 
breakage.  Do not substitute materials.  If your 
glass door breaks, do not  use your unit until it 
has been replaced.
INSTALLATION