Regency FP90 User Manual

Page of 40
FPI FP90 Wood Fireplace
31
HEA
TW
A
VE KIT
HEATWAVE KIT (NOT EPA APPROVED)
Diagram 1: Guide for possible air duct runs and locations. Keep duct length and number of 
bends to a miniumum. Maximum duct length is 20 ft. (6.1m) per kit.
LISTINGS AND CODE 
APPROVALS
This Kit has been approved for use with 
Models EX90 / R90. This kit has been tested in 
accordance with National Safety Standards, and 
has been certifi ed by OMNI Test Laboratories 
for installation and operation in Canada as 
described in these Installation and Operating 
Instructions. 
Check with your local building code agency 
before you begin your installation to ensure 
compliance with local codes, including the 
need for "permits" and follow-up inspections. If 
any problems are encountered regarding code 
approvals, or if you wish clarifi cation on any of 
the instructions contained here, contact your 
local dealer.
GENERAL 
INFORMATION
The Heat Wave Air Duct Kit increases the 
effectiveness of your fi replace by dispersing 
warm air from the fi replace to remote locations in 
the same room or other rooms in your home. 
Up to  two kits may be installed on the fi replace. 
Please Note: Only 1 HeatWave kit may be 
operated at one time. This includes the internal  
blower option as well. 
Important Installation Notes
1)  The appliance installation must conform 
with local codes or, in the absence of local 
codes, with the current Canadian or National 
Gas Codes, CAN1-B149 or ANSI Z223.1 
Installation Codes.
2)  The appliance when installed, must be 
electrically grounded in accordance with 
local codes, or in the absence of local codes 
with the current National Electrical Code, 
ANSI/NFPA 70 or CSA C22.1 Canadian 
Electrical Code.
3)  This kit is tested and safe when installed in 
accordance with this installation manual. 
Please read all instructions before starting 
installation and follow all instructions 
carefully during installation.
4)  Installation of this kit must be performed by 
a qualifi ed service technician.
5)  The Heat Wave Kit must be installed only 
as specifi ed. Any modifi cations of the kit or 
components will void the warranty and may 
cause a fi re hazard. 
6)  Plan the location of the fi replace and the 
warm air duct runs, see diagram 1 as a 
guide for possible duct runs and locations.
 
Maximum Duct Run:  20 ft. (6.1m) per 
kit.
 
NOTE: Airfl ow through the duct system is 
affected by the duct length and number of 
bends.  Keep the length and bends to a 
minimum to maximize performance.
 
PARTS
Included with Kit:
1  946-010  20 ft. (6.1 m) of 6" dia. fl ex pipe
1  946-517  Fan housing assembly
1 910-412 Variable 
wall 
rheostat
1 946-006 Air 
register
1  946-005  Register adaptor frame (thick)
1  946-000  Round Duct collar
1  946-001  Oval Duct collar
1  946-002  Duct adaptor (round to oval)
1 946-045 Insulation 
(60")
 
 Hardware package
If any parts are missing or damaged, contact 
your dealer before starting installation. DO 
NOT install a damaged kit.