Thermostat Wire Table
Option 3: 
WALL THERMOSTAT 
A wall thermostat may be installed if desired, 
connect the wires as per the wiring diagram. 
Use the table below to determine the maximum 
wire length.
Note: Preferable if the thermostat is installed 
on an interior wall.
UltraGlow
®
  offers  an  optional  programmable 
thermostat  or  basic  wall  thermostat  but  any 
250-750  millivolt  rated  non-anticipator  type 
thermostat that is CSA, ULC or UL approved 
may be used.
CAUTION
Do not connect millivolt 
wall thermostat wires
to a 120V wire.
INSTALLATION
Option 1: 
REMOTE CONTROL
Use the UltraGlow
®
Use the UltraGlow
Use the UltraGlow  Remote Control Kit  approved 
®
®
for  this  unit.  Use  of  other  systems  may  void 
your warranty.
The remote control kit comes with a hand held 
transmitter,  a  receiver  and  a  wall  mounting 
plate.
1)  Choose a convenient location on the wall 
to  install  the  receiver  and  the  receptacle 
box (protection from extreme heat is very 
important).  Run  wires  from  the  fi replace 
to that location. Use the Thermostat Wire 
Table.
2)  Connect the two wires to the gas valve. See 
diagram below.
Option 2: 
WALL SWITCH
1)  Run the wire through the right or left side inlet 
opening. Be careful not to damage wire.
Note:  We  recommend  a  maximum  of  15' 
of wire but if you wish to go with a 
longer run, use the Thermostat Wire 
Table.
2)  Connect the wire to the wall switch and install 
into the receptacle box.
CAUTION
Do not connect millivolt 
wall switch wire to a 120V wire.
3)  Install 3 AAA alkaline batteries in transmitter 
and 4 AA alkaline batteries in  the receiver. 
Install the receiver and its cover in the wall. 
Switch  the    remote  receiver  to  "remote" 
mode. The remote control is now ready for 
operation.
CAUTION
Do not connect millivolt remote 
control wires to a 120V wire.
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
50 Ft.
32 Ft.
20 Ft.
12 Ft.
9 Ft.
Recommended Maximum Lead Length 
(Two-Wire) When Using Wall 
Thermostat (CP-2 System)
Wire Size                       Max. Length
Wire Size                       Max. Length