MAINTENANCE 
INSTRUCTIONS
1)  Always turn off the gas valve before cleaning. 
For relighting, refer to lighting instructions. 
Keep the burner and control compartment 
clean by brushing and vacuuming at least 
once a year. When cleaning the logs, use a 
soft clean paint brush as the logs are fragile 
and easily damaged.
2)  Clean  appliance  and  door  with  a  damp 
cloth (never when unit is hot).  Never use 
an abrasive cleaner. The glass should be 
cleaned with a gas fi replace glass cleaner. 
The  glass  should  be  cleaned  when  it 
starts looking cloudy.
3)  The heater is fi nished in a heat resistant 
paint and should only be refi nished with heat 
resistant paint. UltraGlow
®
 uses StoveBright 
®
®
Paint - Metallic Black #6309.
COPY OF THE LIGHTING PLATE INSTRUCTIONS
OPERATING INSTRUCTIONS
Gas Inlet
OFF
TO TURN OFF GAS APPLIANCE
FOR YOUR SAFETY READ BEFORE LIGHTING
YOUR SAFETY
YOUR SAFETY
 LIGHTING INSTRUCTIONS
1) Turn off the flame switch.
2) Push in the gas control knob slightly and turn clockwise      to “OFF”. Do not force.
3) Turn off all electric power to the appliance if service is to be performed.
    You may shut off the pilot during prolonged non use periods to conserve fuel.
1)  Push in gas control knob slightly and turn clockwise               to “OFF”. Knob cannot be turned from 
“PILOT” to “OFF” unless knob is pushed in slightly.  Do not force.
2)  Wait five (5) minutes  to clear out any gas. If you then smell gas STOP! Follow step “B” in the Safety 
Information above on this label.  If you don’t smell gas, go to the next step.
3)  Turn knob  on gas control counterclockwise             to“PILOT”.
4)  Push in control knob all the way and hold in.  Continually push and release the black button on spark 
igniter until pilot lights. Continue to hold the control knob in for about 1/2 minute after the pilot is lit. 
Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 1) to 4). 
If knob does not pop up when released, stop and immediately call your service technician or gas 
supplier. If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your 
service technician or gas supplier.
5)  Turn gas control knob counterclock-wise           to “ON”.
6)  Use rocker switch to operate main burner.
A)
  This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these 
instructions exactly.
B) 
BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell  next to the floor
because some gas is heavier than air and will settle  on the fl oor.
     WHAT TO
  WHA
  WHA
 DO IF YOU SMELL GAS
YOU SMELL
YOU SMELL
-  Do not try to light any appliance.
-  Do not touch any electric switch, do  not use any phone in your building.
-  Immediately  call  your  gas  supplier  from  a  neighbours  phone.  Follow  the  gas  supplier’s
instructions.
-  If you cannot reach your gas supplier, call the fi re department.
C)
  Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not 
push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted 
repair may result in a fire or explosion.
D)
   Do not use this appliance if any part has been under water.  Immediately call a qualified service 
technician to inspect the appliance and to replace any part of the control system and any gas 
control which has been under water.
E)
  This appliance needs fresh air for safe operation and must be installed so there are provisions for 
adequate combustion and ventilation air.
CAUTION:  Hot while in operation. Do not touch. Severe Burns may result. Due 
to high surface temperatures keep children, clothing and furniture, gasoline and
other liquids having flammable vapors away. Keep burner and control compartment
clean. See installation and operating instructions accompanying appliance.
DO NOT REMOVE THIS INSTRUCTION PLATE
WARNING: 
W
W
If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life. Improper
installation, adjustment, alteration, service or maintenance can cause injury
or property damage. Refer to the owner’s information manual provided with
this appliance. For assistance or additional information consult a qualified
installer, service agency or gas supplier
, service agency or gas supplier.
918-473
This appliance must be installed in accordance with local codes, if any; if none, follow the 
National Fuel Gas Code, ANSI Z223.1/NFPA 
ANSI Z223.1/NFP
ANSI Z223.1/NFP 54, or Natural Gas and Propane Installation Codes,
CSA B149.1. (Australia: 
 B149.1. (Australia: 
CSA
CSA
AG601, New Zealand: NZS 5261
AG601, New Zealand: NZS 5261))
FOR UNITS NOT EQUIPPED WITH ELECTRIC SPARK BOXES:
FOR ALL PROPANE UNITS AND UNITS EQUIPPED WITH ELECTRIC SPARK BOXES:
STOP! Read the safety information above on this label.
Gas Inlet
1)  Push in gas control knob slightly and turn to “PILOT” position.
2)  Push in control knob all the way and hold  in until the pilot lights up. Continue to hold the control 
knob in for about 20 seconds after the pilot is lit. Release knob.
3) Push in gas control knob slightly and turn to "ON" position.
4) Turn ON the flame switch.
ELEMENT
THERMO-
ELECTRIQUE
PILOT BURNER
THERMOPILE
VEILLEUSE
NORMAL OPERATING 
SOUNDS OF GAS 
APPLIANCES
It is possible that you will hear some sounds 
from your gas appliance. This is perfectly normal 
due to the fact that there are various gauges 
and types of steel used within your appliance. 
Listed below are some examples. All are 
normal 
operating sounds and should not be considered 
as defects in your appliance.
Burner Tray: 
The burner tray is positioned directly under the 
burner tube(s) and logs and is made of a different 
gauge material from the rest of the fi rebox and 
body. Therefore, the varying thicknesses of steel 
will  expand  and  contract  at  slightly  different 
rates which can cause "ticking" and "cracking" 
sounds. You should also be aware that as there 
are temperature changes within the unit these 
sounds will likely re-occur. Again, this is normal 
for steel fi reboxes.
Pilot Flame:
While the pilot fl ame is on it can make a very 
slight "whisper" sound.
Gas Control Valve:
As the gas control valve turns ON and OFF, a 
dull clicking sound may be audible, this is normal 
operation of a gas regulator or valve.
Unit Body/Firebox:
Different  types  and  thicknesses  of  steel  will 
expand and contract at different rates resulting 
in some "cracking" and "ticking" sounds will be 
heard throughout the cycling process.