Quadra-Fire 7051-158B User Manual

Page of 58
Page  2
7051-158B
December 6, 2011
EDGE 60 Pellet Fireplace 
Hearth & Home Technologies welcomes you to our tradition of 
excellence!  In choosing a Quadra-Fire appliance, you have 
our assurance of commitment to quality, durability, and perfor-
mance.
This commitment begins with our research of the market, 
including ‘Voice of the Customer’ contacts, ensuring we make 
products that will satisfy your needs. Our Research and Devel-
opment facility then employs the world’s most advanced tech-
nology to achieve the optimum operation of our stoves, inserts 
and fi replaces.  And yet we are old-fashioned when it comes to 
craftsmanship.  Each unit is meticulously fabricated and surfaces 
are hand-fi nished for lasting beauty and enjoyment.  Our pledge 
to quality is completed as each model undergoes a quality control 
inspection.      
We wish you and your family many years of enjoyment in the 
warmth and comfort of your hearth appliance.
Thank you for choosing Quadra-Fire.
LOCATION OF CLEARANCE TO COMBUSTIBLES LABEL:  Left Hand Panel of Hopper (Fig. 3)
Testing Lab & Report No.
Manufacture Date
Serial Number
LOCATION OF SERIAL NUMBER LABEL:   Right Inside Edge of Outer Can  (Fig. 2)
Open Front.  Serial Number Label located 
on right side inside edge of outer can.
Slide fireplace out on the rails. Clearance 
to Combustible Label located on left side of 
hopper.
Figure 2 - Serial Number Label
Figure 3 - Clearance to Combustibles 
Label
SAFETY LABEL / ÉTIQUETTE DE SÉCURITÉ
Listed Solid Fuel Room Heater/Pellet Type.  Also suitable for Mobile Home 
Installation.  This appliance has been tested and listed for use in Manufactured 
Homes in accordance with OAR 814-23-9000 through 814-23-909.
R
EDGE 60 PELLET FIREPLACE
PREVENT HOUSE FIRES
Install and use only in accordance with manufacturer's installation 
and operating instructions.  Contact local building or fire officials 
about restrictions and inspection in our area.
WARNING: FOR MOBILE HOMES:  Do not install appliance in a 
sleeping room.  An outside combustion air inlet must be provided.  
The structural integrity of the mobile home floor, ceiling and walls 
must be maintained.
Refer to manufacturer's instructions and local codes for 
precautions required for passing chimney through a combustible 
wall or ceiling.  Inspect and clean vent system frequently in 
accordance with manufacturer's instructions.
Areas of the fireplace incorporating warm or cold air ducts shall be 
enclosed according to the manufacturer’s installation instructions.
Components required for all installations:  Outside Air Kit, Part 
Number OAK-3.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER 
APPLIANCE.
Use a 3 or 4 inch (76-102mm) diameter type "L" or "PL" venting system.
CAUTION: Combustion air openings are not to be obstructed.
CAUTION: It is necessary that this fireplace have air for proper 
operation. Please refer to the owners mannual for possible 
consequences of improper ventilation.
Tested to: ASTM E1509-04, ULC S628-93, 
ULC/ORD-C1482-M1990 Room Heating Pellet Burning Type,  (UM) 
84-HUD FOR USE ONLY WITH PELLETIZED WOOD.  SEE OWNER’S 
MANUAL FOR OTHER FUEL OPTIONS.  
OMNI-Test Laboratories, Inc. has determined that this appliance 
complies with Canadian Standards Association (CSA) B415.1 
and Title 40 of the U.S. Code of Federal Regulations, Part 60, 
SubPart AAA.OMNI-Test  Laboratories Accrediations:    The 
Standards Council of Canada, the American National Standards 
Institute, and the U.S. Environmental Protection Agency.
Input Rating:  52,000 BTU/HR.
Electrical Rating:  115 VAC, 60 Hz, Start 5 Amps, Run 1.25 AMPS.
DANGER:  Risk of Electric Shock.  Disconnect Power Before 
Servicing Unit. 
Replace glass only with 5mm ceramic available from your dealer.  
To start, set thermostat above room temperature, the stove will light 
automatically.  To shutdown, set thermostat to below room 
temperature. 
 
For further instruction refer to owner's manual.
Keep viewing & ash removal doors tightly closed during operation.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
7051-148C
NE PAS ENLEVER L'ÉTIQUETTE
CAUTION
:
 
ATTENTION:
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN, CLOTHING AND FURNITURE 
AWAY. CONTACT MAY CAUSE SKIN BURNS.  SEE NAMEPLATE AND INSTRUCTIONS.  Operate 
this unit only with the fuel hopper lid closed.  Failure to do so may result in emissions of products of 
combustion from the hopper under certain conditions.  Maintain hopper seal in good condition. Do not 
overfill hopper.
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE 
L'INSTALLATION. LE CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU.  VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS. Opérez cet 
appareil avec le couvercle de la trémie fermé. Le défaut de ne pas suivre les instructions peut résulter, sous certaines conditions, 
en une combustion des émissions des produits venant de la trémie. Ne pas remplir la trémie trop pleine. 
A  Surfaces Mur de arrières   
0 in (0mm)
B  Surfaces Mur de côté 
0 in. (0mm)
C  Surfaces supérieurs à la boutisse  
0 in. (0mm)
D  Du conduits des combustibles 
*
E  Protection du plancer dessus cheminéel:   Ne pas requis
A  Standoff to Back Wall 
 
0 in. (0mm)
B  Standoff to Side Walls 
 
0 in (0mm)
C  Top Standoff to Header   
0 in (0mm)
D  Vent Pipe to Combustible  
*
E  Floor Protection under Fireplace 
None Required
PRÉVENTION DES FEUX DE MAISON
Installez et utilisez en accord avec les instructions d'installation et d'opération du 
fabricant. Contactez le bureau de la construction ou le bureau des incendies au 
sujet des restrictions et des inspections d'installation dans votre voisinage. Ne pas 
obstruez l'espace en dessous de l'appareil.
AVIS - Pour Les Maisons Mobiles:  Ne pas installer dans une chambre à coucher. 
Un tuyau extérieur de combustion d'air doit être installé et ne doit pas être obstrué 
lorsque l'appareil est en usage. La structure intégrale du plancher, du plafond et 
des murs de la maison mobile doit être maintenue intacte.
Référez vous aux instructions du fabricant et des codes locaux pour les précautions 
requises pour passer une cheminée à travers un mur ou un plafond combustibles, 
et les compensations maximums.
Inspectez et nettoyez la cheminée fréquemment.
Domaines de la cheminée incorporant les gaines d'air chaud ou froid doivent être 
enfermés en conformité avec les instructions d'installation du fabricant.
 Les composants requis pour tout l'installations. Assemblage d'air extérieur, Numéro de 
Pièce OAK-3.
Ne pas connecter cet appareil à une cheminée servant un autre appareil.
Utilitsez le système de ventilation de 3 or 4 inch (76-102mm) de diametre de type “L” ou “PL”.
ATTENTION: ouvertures d'air de combustion ne doivent pas être obstruées.
ATTENTION: Il est nécessaire que ce foyer ont l'air d'un bon fonctionnement. S'il vous plaît 
se référer à des propriétaires mannual pour les conséquences possibles d'une mauvaise 
ventilation.
Testé à: ASTM #1509-04, ULC S628-93, ULC/ORD-C1482-M1990 Room 
Heating.  Pellet Burning Type, UM) 84-HUD POUR USAGE AVEC  LES 
BOULETTES DE BOIS.  VOIR LE MANUAL DU PROPRIÉTAIRE POUR 
D’AUTRES OPTIONS DE CARBURANT.
OMNI-Test Laboratories, Inc. a déterminé que cet appareil se conforme avec la 
norme de l’Association Canadienne de normalisation (CSA) B415.1 ainsi que 
le Titre 40 du Code Fédéral de Régulations des États-Unis, partie 60, 
sous-partie AAA.   Accréditations OMNI-Test Laboratories : Le Conseil 
Canadien des Normes (CCN/SCC), l’Institue des Standards Nationaux 
Américain (ANSI) et l’Agence de Protection Environnemental (EPA
).
Puissance de Rendement:  52,000 BTU/HR
Puissance Électrique: 115 VAC, 60 Hz, Début 5 Amps, Courir 1.25 Amps, 
DANGER: Il y a risque de décharge électrique.  Déconnectez le fil électrique de la prise 
de contact avant le service.  Remplacez la vitre seulement avec une vitre céramique de 
5 mm disponible chez votre fournisseur.
Pour allumer, monter la température du thermostat au dessus de la température de la 
pièce, le poêle s'allumera automatiquement.  Pour éteindre, descendre la température 
du thermostat en dessous de la température de la pièce.  Pour des instructions 
supplémentaires, référez vous au manuel du propriétaire.  Gardez la porte d'ouverture 
et la porte des cendres fermées hermétiquement durant l'opération.
Appareil de chauffage de combustible solide/de type de boulettes.  Accepté dans 
l'installation dans les maisons mobiles.  Cet appareil a été testé et enregistré pour l'usage 
dans les Maisons Mobiles en accord avec OAR 814-23-9000 jusqu'à 814-23-909.
DO NOT REMOVE THIS LABEL
F  Floor Protection Hearth Extension From Door Opening  6 in (152mm)
G  Floor Protection to the Side of Door Opening 
6 in (152mm)
* Use Pipe Manufacturer’s Listed Clearances, 1 inch (25mm) Minimum
*Voir le fabricant pour les espaces libres des conduits enregistré, 1 inch (25mm) minimum
F  Portection du plancer agrandissement du foyer à ouverture du port:  6 in (152mm)
G  Portection du plancer de côté à ouverture du port:  
 6 in (152mm)
C
A
B
A
F
G
ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES
ALL MATERIAL USED FOR FLOOR PROTECTION MUST BE NON-COMBUSTIBLE
O - T   L
Tested and 
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
JAN  FEB  MAR APR  MAY JUNE 
7051-159C
Fabriqué par
:
1445 Highway North, Colville, WA  99114
Manufactured by:
www.quadrafire.com
R
EDGE 60 PELLET 
FIREPLACE
Report 
Rapport
#061-F-75-6.2
007007
O - T   L
Tested and 
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
 
JULY  AUG  SEP  OCT NOV  DEC
2012
2013
2014
Made in U.S.A. 
of US and 
imported parts.
Fabriqué aux 
États-Unis-d’Amérique par des 
pièces d’origine américaine et 
pièces importées.