Quadra-Fire 7051-158B User Manual

Page of 58
Page  54
7051-158B
December 6, 2011
EDGE 60 Pellet Fireplace 
When describing the location of a component, 
it is always AS YOU FACE THE FRONT OF 
THE APPLIANCE.
B. Component Functions
1.  Auto-Clean Motor
Location:  Behind and under the fi repot on the left side, inside 
the convection air chamber
Function:  It automatically opens and closes the fi repot fl oor 
so ashes can fall into the ash pan.
2.  Auto-Clean Switch
Location:  On top of the auto-clean motor
Function:  Communicates to the control board when the fi repot 
fl oor is open and when the auto-clean system has completed 
its cycle and is back in the home (closed) position.
3.  12 Volt Battery Back-Up Cable (Optional Accessory)
Location: Plugs into the appliance at the lower left front of 
the appliance. 
Function:  An icon will display on the wall control when the 
appliance has lost main power and is running on battery 
back-up.
4.  Combustion (Exhaust) Blower
Location:  Mounted in the bottom right rear of appliance.
Function:  Pulls the exhaust from the appliance and pushs it 
out through the venting system.  
5.  Control Board
Location:  Lower left side of appliance.
Function:   Controls the functioning of the appliance and 
communicates with the wall control.  The control board can 
only be opened by an authorized dealer.
6.  Convection Blower
Location:  Mounted at the bottom left rear of the appliance
Function:  Pushes heated air through the heat exchange 
system into the room. 
7.  Door Switch
Location:  Mounted on the right side of the fi rebox behind 
the door handle
Function:  Senses when the door is open and will display an 
icon on the wall control and will turn off the auto-clean system 
and feed motor for safety.
8.  Feed System
Location:  On the right side of the appliance and can be 
removed as an entire assembly.  The assembly includes 
the feed motor, mounting bracket, bearing and feed spring 
(auger).
Function:  The hollow feed spring (auger) pulls pellets up the 
feed tube from the hopper area and drops them down the 
feed chute into the fi repot 
9. Firepot
Location:  Inside fi rebox and is made of high quality ductile 
iron.
Function:  The fl oor of the fi repot automatically opens for 
cleaning and is operated by the auto-clean fi repot system.  
The fl oor needs to return to a completely closed position or 
the appliance will not operate properly.
10. Fuses
Location:  One
 AC fuse and one DC fuse is located on the 
inside of the control board and a third fuse is located in the 
power supply.  Figures 54.1 & 54.2 on page 54. 
Function:  
The AC fuse operates the igniter and the DC 
fuse operates all of the other components.
  The third fuse 
protects the components in the power supply. A fuse will 
blow should a short occur and shut off power to the appli-
ance.  The fuses can only be replaced by an authorized 
dealer.
11.  Heat Exchanger
Location:  B
ehind the baffl e.  
Remove the cast iron baffl e 
to access the heat exchanger.  
Function:  T
ransfers heat from the exhaust system into the 
convection air chamber.
12.  Hopper Lid Switch
Location:  Lower
 front right side of appliance on the power 
switch cover.
Function:  S
enses whether the hopper lid is open and dis-
plays an icon on the wall control and will turn off the feed 
motor.
13.  Interlock Switch
Location:  Lower 
front right side of appliance behind power 
switch.
Function:  Causes the auger to stop functioning and will be 
opened when the appliances slides are extended.
14.  Igniter (Heating Element)
Location:  M
ounted on the base of the fi repot.
Function:  Combustion air travels over the red hot igniter 
creating super heated air that ignites the pellets or other 
fuels.  
15.  Power Receptacle
Location:  L
ower rear of the appliance
Function:   Check the wall receptacle for 120 volt, 60 Hz 
(standard current).  Make sure the outlet is grounded and 
has the correct polarity.