INST
ALLA
TION
SIDE NAILING STRIPS
The side and top nailing strips come attached to the unit. There is 1 plate 
on each side, and 1 on the top, that can be folded out as required.
Nailing
Strips
UNIT ASSEMBLY 
PRIOR TO 
INSTALLATION
The Top Facing Support, the Side Nailing Strips and the 2 Top Standoffs 
must be correctly positioned and attached to the top before unit is 
slipped into position. 
TOP STANDOFF ASSEMBLY
The top standoffs are shipped in a fl at position and must be folded into 
shape and attached.
1)  Remove the standoffs from the fi replace top.
2)  Take each standoff and bend into the correct shape. Bend up at the 
bend lines until the screw holes in the standoff and the pre-punched 
screw holes on the fi replace  top line up. 
3)  Attach the standoff securely to the top with 2 screws per standoff 
(on opposite corners).
Nailing Strips shown folded out.
VENTING INTRODUCTION
The  HZ54  uses  the  "balanced  fl ue"  technology Co Axial system. The 
inner liner vents products of combustion to the outside while the outer 
liner draws outside combustion air into the combustion chamber thereby 
eliminating the need to use heated room air for combustion and losing 
warm room air up the chimney.
Note: These fl ue pipes must not be connected to any other 
appliance.
The gas appliance and vent system must be vented directly to the outside 
of the building, and never be attached to a chimney serving a separate solid 
fuel or gas burning appliance. Each direct vent gas appliance must use 
it's own separate vent system. Common vent systems are prohibited.
IMPORTANT NOTE
Framing depth measurement is noted with the 
side nailing strips set as far forward on the 
fi rebox as possible.  The side nailing strips can 
be adjusted back up to 1” to allow for varying 
thicknesses in non-combustible material & wall 
fi nishes.