Regency I1100S User Manual

Page of 20
Regency Wood Insert & Hearth Heater
11
BRICK FLUE BAFFLE &
SECONDARY AIR TUBE
INSTALLATION
The fl ue baffl e system located in the upper area 
of the fi rebox is removable to make cleaning 
your chimney system easier.  The brick baffl es 
must be installed prior to your fi rst  fi re.  Smoke 
spillage and draft problems may occur if  the 
baffl es are improperly positioned. 
 Check the 
position of the brick baffl es on a regular basis as 
they can be dislodged if too much fuel is forced 
into the fi rebox. 
The Large Insert  I3100L is shipped with one of 
the secondary air tubes loose inside the fi rebox. 
It needs to be installed after the brick baffl e are 
installed. Follow the directions below.
Large Insert I3100L
 
The unit arrives with the third air tube (from the 
front) and the 2 baffl e bricks on the fl oor of the 
fi rebox. The baffl e bricks are positioned fi rst and 
then the air tubes are installed. 
1)  Slide the left baffl e brick over the  two rear 
air tubes and then push it all the way to the 
left side of the fi rebox. 
Front View
Large Insert (I3100L)
Small Insert  (I1100S)
Hearth Heater (H2100M)
2)  Tilt the fi rst Baffl e Brick down and then slide 
the 2nd Baffl e Brick up and back.  Reposition 
both baffl e bricks fl at on the air tubes. 
3)  Important: push both baffl e  bricks  so 
they are tight against the side walls. 
4)  Install the third air tube into the holes on the 
side channels. The notch goes on the right 
hand side with the air holes facing forward 
toward the door opening.  If the tube will not 
slide in easily, simply use a pair of vise grips 
or pliers and tap it into place with a hammer.  
A tighter fi t will ensure the tube will not move 
when the unit is burning. 
INSTALLATION
FLOOR PROTECTION
Please check to ensure that your fl oor protection 
and hearth will meet the standards for clearance 
to combustibles. Your hearth extension must be 
made from a non-combustible material.
FIREBRICK ASSEMBLY
Firebrick is included to extend the life of your 
insert and radiate heat more evenly.  Check to 
see that all fi rebricks are in their correct posi-
tions and have not become misaligned during 
shipping.  
DOOR HANDLE
Attach spring handle by rotating counter clock-
wise onto rod.  Ensure that the rod fi ts into the 
entire length of the spring handle. 
Note:  When cleaning the chimney reverse 
the above procedures, removing 
the air tube and baffl e  bricks  and 
then replace them when cleaning is 
completed.