GAS PIPE 
PRESSURE TESTING
The appliance must be isolated from the gas supply piping system by closing 
its individual manual shut-off valve during any pressure testing of the gas 
supply piping system at test pressures equal to or less than 1/2 psig. 
(3.45 kPa).  Disconnect piping from valve at pressures over 1/2 psig.
The manifold pressure is controlled by a regulator built into the gas control, 
and should be checked at the pressure test point.
NOTE: To properly check gas pressure, both inlet and manifold 
pressures should be checked using the valve pressure ports 
on the valve.
1)  Make sure the valve is in the "OFF" position.
2)  Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise 
with a 1/8" wide fl at screwdriver.
3)  Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" 
ID hose.
4)  Light the pilot and turn the valve to "ON" position.
5)  The pressure check should be carried out with the unit burning and 
the setting should be within the limits specifi ed on the safety label.
6)  When fi nished reading manometer, turn off the gas valve, disconnect 
the hose and tighten the screw (clockwise) with a 1/8" fl at screwdriver. 
Note: Screw should be snug, but do not over tighten.
SIT VALVE DESCRIPTION
1) Gas 
on/off 
knob
2) Manual 
high/low 
adjustment
3) Pilot 
Adjustment
4) Thermocouple 
Connection 
option
5)  Manifold (Outlet) Pressure Tap
6) Inlet 
Pressure 
Tap
7) Pilot 
Outlet
8)  Main Gas Outlet
9) Alternative 
TC 
Connection 
Point
1
2
3
4
5
6
IN
OUT
INSTALLATION