MAINTENANCE
MAINTENANCE
VALVE REPLACEMENT
1)  Open the left and right side faceplate 
panels.
2)  Remove the bottom louver by pulling out.
3)  Remove the glass door.
 
a)  Pull off the left side spring hook that holds 
the door in place.  While holding the hook turn 
it upside down and place it into the middle 
opening on the top side mounting bracket. 
Repeat for right side
 b) 
 
Swing the door out 45 degrees and lift up 
and out.
7)  Disconnect the gas connection to the 
valve.
8)  Disconnect the ignitor wire from the DC 
Sparker.
9)  Disconnect the valve wires from the DC 
Sparker.
10) Unplug the 2 connectors from the valve.
DC Sparker Wires
4)  Remove the logs.
5)  Remove brick panels, if installed.
6)  Remove the valve shield by undoing the 2 
screws.
Valve Shield
Spring Hook
Top Mounting Bracket