IMPORTANT MESSAGE 
SAVE THESE 
INSTRUCTIONS
The FPI Direct Vent Gas Insert must be installed 
in accordance with these instructions. Carefully 
read all the instructions in this manual fi rst. Con-
sult the building authority having jurisdiction to 
determine the need for a permit prior to starting 
the installation.
NOTE:  Failure to follow the instructions could 
cause a malfunction of the heater which could 
result in death, serious bodily injury, and/or 
property damage.  Failure to follow these 
instructions may also void your fi re insurance 
and/or warranty. 
FOR YOUR SAFETY
This appliance requires air for proper combustion. 
Always provide adequate combustion and 
ventilation air.  Follow instructions and information 
in CSA B149.1 (in Canada) or the National Fuel 
Gas Code ANS Z223.1/NFPA (in the USA), 
regarding requirements for combustion and 
ventilation air.
GAS PRESSURE 
TESTING
The appliance must be isolated from the gas 
supply piping system by closing its individual 
manual shut off valve during any pressure testing 
of the gas supply piping system at test pressures 
equal to or less than
1/2 psig. (3.45 kPa).
SPECIFICATIONS
At pressures over 1/2 psig, the pipe to the unit 
must be disconnected.
Gas Input Capacity:  
 Natural 
Gas 
23,500 
Btu/h
 Propane 
21,500 
Btu/h
Min. Input:
 Natural 
Gas 
12,500 
Btu/h
 Propane 
11,000 
Btu/h
Fuels:  Approved for use with both natural gas, 
and propane. Approved as is for use at 0' to 
4,500' (0-1370m).
Electrical:            120V A.C. system.
Circulation Fan:  Variable speed, 127 CFM.
Log Set:               Ceramic fi bre, 6 per set.
Vent System:       3" co-linear aluminum fl ex  
 
             or 2" intake with 3" exhaust.
INSTALLATION INTO A 
SOLID FUEL BURNING 
FIREPLACE OR 
FACTORY BUILT 
FIREPLACE
The L234 Gas Inserts have been tested and 
approved to be vented into any masonry 
fireplace or approved solid fuel burning 
factory built fi replace that will allow the insert 
to physically fi t into the fi rebox. Refer to the 
"Minimum Fireplace Opening" section.
If the factory built fi replace* height is too low 
for your Insert, you may remove the smoke 
baffl e plate and damper from the factory 
built fi replace as long as these items are 
saved and are reinstalled in the event that 
the Insert is removed. NOTE: Any alterations 
made to the listed solid fuel burning factory 
built fi replace may void the listing of the 
fi replace. Cutting any sheet-metal parts of 
the fi replace, in which the gas fi replace insert 
is to be installed, is prohibited.
If the factory-built fi replace has no gas 
access hole(s) provided, an access hole of 
1.5" (37.5mm) or less may be drilled through 
the lower sides or bottom of the fi rebox in 
a proper workmanship like manner. This 
access hole must be plugged with non-
combustible insulation after the gas supply 
line has been installed. 
The fi replace  and  fi replace chimney must 
be clean and in good working order and 
constructed of non-combustible materials 
and chimney cleanouts must fi t  properly. 
Refractory, glass doors, screen rails, screen 
mesh, and log grates can be removed 
from the fi replace before installing the gas 
fi replace insert. Smoke shelves, shields 
and baffl es may be removed if attached by 
mechanical fasteners. A tight seal between 
the gas fi replace insert fl ue collar and the 
fi replace chimney must be made to prevent 
heat loss.
*Check with your local inspector before 
commencing with this installation.
BEFORE YOU START
Safe installation and operation of this appliance 
requires common sense, however,  we are 
required by the Canadian Safety Standards 
and ANSI Standards to make you aware of 
the following:
General Safety Information
1)  The appliance installation must conform 
with local codes or in the absence of local 
codes, with CAN/CSA B149.1 (in Canada) 
or the National Fuel Gas Code ANSI Z223.1 
NFPA 54 in the U.S.A. This appliance should 
be installed by a qualifi ed gas fi tter technician 
only.
2)  Installation and repair should be done 
by a qualifi ed service person.  
3)  The appliance should be inspected 
before use and at least annually by 
a professional service person. More 
frequent cleaning may be required due 
to excessive lint from carpeting, bedding 
material, animal hair, etc.  It is imperative 
that control compartments, burners 
and circulating air passageways of the 
appliance be kept clean. 
4)  See general construction and assembly 
instructions. This appliance may only be 
installed in a vented, noncombustible 
fi replace.
5)  This appliance is Listed for bedroom 
 
installations when used with a Listed Millivolt 
Thermostat. Some areas may have further 
requirements, check local codes before 
installation.
6)  Always connect this appliance to a vent 
system vent that is run (or routed) to the 
outside of the building envelope. Never vent  
to another room or inside a building. Make 
sure that the vent is properly sized and is 
of adequate height to provide the proper 
draft.  
7)  Inspect the venting system annually for 
blockage and any signs of deterioration.   
8)  Any glass removed for servicing must be 
replaced prior to operating the appliance.  
9)  WARNING: Failure to position the parts 
in accordance with the diagrams in 
this manual or failure to use only parts 
specifi cally approved with this appliance 
may result in property damage or 
personal injury.
10) To prevent  injury, do not allow anyone who 
is unfamiliar with the operation to use the 
fi replace.  
Installer must mechanically attach the supplied 
label to the inside of the fi rebox of the fi replace 
into which the gas fi replace insert is installed.
"WARNING: This fi replace has been converted 
for use with a gas fi replace insert only and 
cannot be used for burning wood or solid fuels 
unless all original parts have been replaced, 
and the fi replace re-approved by the authority 
having jurisdiction."