PGS TC36 AR User Manual

Page of 36
4      36ARB2 
050505-36
Minimum Clearances to Combustibles:
Side standoffs ...................... 0 in. 
(0 mm)
Back standoffs ..................... 0 in. 
(0 mm)
Top standoffs ....................... 0 in. 
(0 mm)
Bottom of appliance ............. 0 in. 
(0 mm)
Adjacent sidewall ................. 4 in. 
(102 mm)
Ceiling to appliance ........... 24 in. 
(610 mm)
*Mantel to appliance  ..........See Figure #2
**Maximum
    Mantel extension    ..........See Figure #2 
 
Mantel support ..................... 4 in. 
(102 mm)
Vertical vent pipe ........... 1-3/4 in. 
(45 mm)
Horizontal vent pipe
     Top ........................... 1-3/4 in. 
(45 mm)
     Sides ........................ 1-3/4 in. 
(45 mm)
     Bottom ...................... 1-3/4 in. 
(45 mm)
Fig. # 3
CEILING
ADJACENT
WALL OR
MANTEL 
SUPPORT
MANTEL
UNIT MAY BE RECESSED UP TO 
6" WITH NON-COMBUSTIBLE 
MASONRY TYPE MATERIAL
D
E
F
C
B
A
 
9" 
 
   D 
 
 12"
 
6" 
 
   E 
 
6 3/4"
 
3" 
 
   F 
 
1 1/2"
COMBUSTIBLE FRAMING AND 
FINISH WALL ABOVE STANDOFFS
STANDOFFS
STEEL FRAMING
FIREPLACE FRONT
TOP OF LINTEL BAR
MANTEL CLEARANCE CHART
REF.
MANTEL
DEPTH
REF.
MANTEL
CLEARANCE
Fig. # 2
*
**
MAY USE COMBUSTIBLE FACING 
MATERIAL IN THIS AREA
NON-COMBUSTIBLE 
FINISH MATERIAL
SEE FIG #7
NON-COMBUSTIBLE ZONE. 
DO NOT INSTALL ANY 
COMBUSTIBLE MATERIAL, 
ELECTRICAL WIRING OR 
GAS PLUMBING IN THIS 
AREA.