PGS TC36 AR User Manual
4 36ARB2
050505-36
Minimum Clearances to Combustibles:
Side standoffs ...................... 0 in.
(0 mm)
Back standoffs ..................... 0 in.
(0 mm)
Top standoffs ....................... 0 in.
(0 mm)
Bottom of appliance ............. 0 in.
(0 mm)
Adjacent sidewall ................. 4 in.
(102 mm)
Ceiling to appliance ........... 24 in.
(610 mm)
*Mantel to appliance ..........See Figure #2
**Maximum
Mantel extension ..........See Figure #2
Mantel extension ..........See Figure #2
Mantel support ..................... 4 in.
(102 mm)
Vertical vent pipe ........... 1-3/4 in.
(45 mm)
Horizontal vent pipe
Top ........................... 1-3/4 in.
Top ........................... 1-3/4 in.
(45 mm)
Sides ........................ 1-3/4 in.
(45 mm)
Bottom ...................... 1-3/4 in.
(45 mm)
Fig. # 3
CEILING
ADJACENT
WALL OR
MANTEL
SUPPORT
WALL OR
MANTEL
SUPPORT
MANTEL
UNIT MAY BE RECESSED UP TO
6" WITH NON-COMBUSTIBLE
MASONRY TYPE MATERIAL
6" WITH NON-COMBUSTIBLE
MASONRY TYPE MATERIAL
D
E
F
C
B
A
A
9"
D
12"
B
6"
E
6 3/4"
C
3"
F
1 1/2"
COMBUSTIBLE FRAMING AND
FINISH WALL ABOVE STANDOFFS
FINISH WALL ABOVE STANDOFFS
STANDOFFS
STEEL FRAMING
FIREPLACE FRONT
TOP OF LINTEL BAR
MANTEL CLEARANCE CHART
REF.
MANTEL
DEPTH
REF.
MANTEL
CLEARANCE
Fig. # 2
*
**
MAY USE COMBUSTIBLE FACING
MATERIAL IN THIS AREA
MATERIAL IN THIS AREA
NON-COMBUSTIBLE
FINISH MATERIAL
SEE FIG #7
FINISH MATERIAL
SEE FIG #7
NON-COMBUSTIBLE ZONE.
DO NOT INSTALL ANY
COMBUSTIBLE MATERIAL,
ELECTRICAL WIRING OR
GAS PLUMBING IN THIS
AREA.
DO NOT INSTALL ANY
COMBUSTIBLE MATERIAL,
ELECTRICAL WIRING OR
GAS PLUMBING IN THIS
AREA.