Hearth & Home Technologies COLBAY-FS-B User Manual

Page of 49
10/08
Page  23
Quadra-Fire  •  Columbia Bay  •  250-5195 Rev. K
A
B
C
Figure 6.5
   Turn control knob to the OFF position, ensure that 
gas supply to the valve has been turned off. Using a Torx 
TH20, or slotted screwdriver, remove the three pressure reg-
ulator mounting screws
 (A), pressure regulator tower (B)
and diaphragm
 (C).
2. Valve Regulator Replacement
Remove upper and lower back shield.  Loosen the set col-
lars on the extension rods with the 3/32 in. Allen wrench.  
Remove the rods and adapter cap.
Fire Risk.
Explosion Risk.
 
Disconnect any electrical cords and 
turn off gas supply to unit before 
proceeding if converting fuel on an 
appliance already fully installed.
WARNING
Fire Risk.
Explosion Risk.
 
If the information in these instructions is 
not followed exactly, a fi re, explosion or 
production of carbon monoxide may result 
causing property damage, personal injury 
or loss of life.  
•  The qualifi ed service agency is responsible 
for the proper installation of this conversion 
kit.  The installation is not proper and 
complete until the operation of the converted 
appliance is checked as specifi ed in the 
manufacturer’s instructions supplied with 
the kit.
WARNING
E
D
F
Figure 6.6
   Ensure that the rubber gasket 
(D) is properly posi-
tioned and install the new HI/LO pressure regulator assem-
bly to the valve using the new screws 
(E) supplied with the 
kit. Tighten screws securely. (Reference torque = 25 in./lb.)  
Install the enclosed identifi cation label 
(F) to the valve body 
where it can be seen.
Fill out the conversion label and attach it to the valve cover.
WARNING
Fire Risk.
Explosion Risk.
Gas Leak Risk.
•  Rubber gasket must be seated properly on valve 
face.
•  Do no install a valve or regulator that has been 
dropped.