Sierra Products B Model Leaflet

Page of 2
5061 Brooks St. Ste B Montclair, CA 91763
800-527-4790 Fax 1-909-399-3357
www.sierraproductsinc.net
P/N Fan Motor Brush Service 08 10/08
B Model Fan Motor Brush 
Service Instruction 
Figure 1
Figure 3
Figure 2
Figure 4
OVERVIEW
The EasyFire heater is equipped with a long life DC fan m otor (Figure
1)
. This m otor utilizes a special brush m aterial that m ay require
additional break in tim e to properly wear in or seat the brushes. W hen
the m otor is new the brush has a contoured end that allows for 
m inim um  contact initially to facilitate the break in. As this wears the full
width of the brush begins to contact the arm ature allowing for proper
operation.
W e have found that a sm all quantity of m otors have not im m ediately
seated the brushes causing a m otor fault light (Red Flashing LED) on
the control panel. The m otor fault condition requires the unit to be
powered down (unplugged) to clear. This condition m ay also be the
result of a feed jam b. The control system  is designed to address both
inoperative fan and feed m otor in the sam e m anner to protect the user
and m inim ize further dam age to the unit. The fan m otor condition is
easily corrected by dressing the brushes and reinstalling them .
Testing for a fan m otor brush problem  is accom plished by two
m ethods. After recycling the heater by unplugging and reestablishing
power. Press the “Fan” switch only. If the fan runs push the Clean
button and allow the m otor speed to increase to full speed. If the “Red
Safety Light” does not light then the fan m otor is generally considered
in proper operation. If pressing the Off button then pressing a run
button such as Low provides a short period then a flashing “Red Safety
Light” the feed m ay be jam bed. This can be cleared by rem oving pellets
from  hopper and rem oving access cover. If the safety light operates on
“fan or clean” then accom plish the following service.
Tools Required: #2 Phillips screw driver, m edium  flat blade, sm all flat
blade, #200 or fine sand paper strip (Figure 2).
Accessing the
m otor for brush
service:
  The fan
m otor is accessed
from  the rear of the
heater by rem oving
the phillips screws
on the upper and
lower rear access
panels. Once the
panels are free tilt
the upper panel to
the rear allowing the
fan shroud to clear
the convection fan
blade  (Figure 3)
Rem oving the w ire harness connections : Using care not to bend the fan blade, carefully use a flat blade screw driver
to help pry off the red and black  m otor wire term inals (Figure 4). Note the brush holders have a corresponding red and
black base to confirm  wire connections. 
Brush holder with access