Enviro ENVIRO User Manual
15
Initial Installation
QUALIFIED INSTALLERS ONLY
The gas line, 3⁄8 inch NPT, can be brought to either the right side, the left side, or the bottom of
the fireplace. If this set up is inconvenient, the electrical wire and the gas line configuration can be
reversed.
The location should be chosen so the fireplace must be at least 36 inches (91.4 cm) from drapes, doors
The location should be chosen so the fireplace must be at least 36 inches (91.4 cm) from drapes, doors
and other combustibles. The framed opening should also be a minimum of 6.5 inches (16.5 cm) from the
nearest perpendicular wall (sidewall to the edge of the opening).
The Retreat is designed so it can be installed at floor level without a required hearth
.
C
ORNER
I
NSTALLATION
:
R
AISED
F
IREPLACES
AND
H
EARTHS
:
Even though the Retreat can be installed at floor level without a hearth, there are a few options with
raised fireplaces: raised with a raised hearth (Figure 20), raised with a floor level hearth (Figure 21), or
raised with no hearth (Figure 22). If the fireplace is raised, it cannot be placed within 133⁄4 inches (35cm)
of the ceiling. When installing a raised fireplace, it is imperative that the support stand is strong enough
to hold the weight of the fireplace (up to 200lb [90.7Kg]) and venting.
Figure 19. Dimensions for a corner installation.
23" (584mm)
39
5
/
16
" (998mm)
1
/
2
" (13mm)
Front Facing
2"x6"
Stud
27
13
/
16
" (706mm)
8
1
/
4
"
(210mm)
The dimensions for installing a
fireplace in the corner of a room
are given in Figures 19. Refer
to “I
NITIAL
I
NSTALLATION
- V
ENT
C
ONFIGURATIONS
AND
R
ESTRICTOR
S
ETTINGS
” for allowable pipe
lengths.
Do not interfere with the
Do not interfere with the
structural integrity of the walls.