MASTER LOCK 100000 BTU/Hr User Manual

Page of 24
8
101585
OPERATION
Continued
To Stop Heater
1. Unplug power cord from outlet.
To Restart Heater
1. Wait 2 minutes after stopping heater.
2. Repeat steps under To Start Heater, page 7.
1. Drain fuel tank.
Note: 
Some models have drain plug on underside of fuel tank. If so, remove
drain plug to drain all fuel. If heater does not have drain plug, drain fuel through
fuel cap opening. Be sure all fuel is removed.
2. Replace drain plug if used.
3. Add one gallon (4 liters) of clean kerosene to fuel tank.
4. Attach fuel cap.
5. Move heater forwards and backwards to stir fuel.
6. Remove fuel cap or drain plug and drain fuel tank. Be sure all fuel is removed.
7. Replace fuel cap or drain plug. Properly dispose of old and dirty fuel.
8. Store heater in dry place. Make sure storage place is free of dust and corrosive
fumes.
IMPORTANT:
 
Do not store kerosene over summer months for use during next
heating season. Using old fuel could damage heater.
STORAGE
PREVENTATIVE
MAINTENANCE
SCHEDULE
Item
How Often
How To
Fuel tank
Flush every 150-200 hours
See Storage above.
   of operation or as needed.
Air output and
Replace every 500 hours of
See Air Output, Air Intake,
   lint filters operation or once
   and Lint Filters, page 12.
   a year.
Air intake
Wash and dry with soap and
See Air Output, Air Intake,
filter
   water every 500 hours of
   and Lint Filters, page 12.
   operation or as needed.
Fuel filter
Clean twice a heating season
See Fuel Filter, pages 10
   or as needed.
   and 11.
Spark plug
Clean and regap every 600
See Spark Plug, page 11.
   hours operation or replace
   as needed.
Fan blades
Clean every season or as needed.
See Fan, page 15.
Motor
Not required/permanently
   lubricated
WARNING
Never service heater while it is plugged in, operating, or
hot. Severe burns and electrical shock can occur.