Roberts Gorden EP 100 Leaflet

Page of 2
Model
EP 100
EP 201
EP 203
EP 301
Maximum Number of Flow Units* (CORAYVAC
®
)
66
110
110
224
Maximum Number of VANTAGE
®
EV Burners**
80,000
4
6
6
110,000
4
6
6
140,000
4
6
6
170,000
2
4
4
200,000
2
4
4
Motor Specifications
Horse Power (Hp)
1/3
3/4
3/4
2***
Phase (PH)
1
1
1
Hertz (HZ)
60
60
60
60
Voltage (V)
115/230 
115/230
230  
230
Full Load Amp (Amps)
4.8/2.4
6.6/3.3
3.0
11.5
R.P.M.
3450
3450
3450
3450
Maximum Ambient Temperature
40°C
40°C
40°C
40°C
Motor Frame
56
56
56
90
Motor Enclosure
TENV
TENV
TEFC
TEFC
Thermal Overload Protection
Automatic
Automatic
None
Automatic
Duty
Continuous
Continuous
Inverter/Continuous
Continuous
Noise Level @ 5ft. (DBA)
70
70
Drive
Direct
Direct
Direct
Direct
Inlet/Outlet (In.)
4/4
4/4
4/4
6/6
Type Bearings
High Temperature Sealed Ball Bearing
Warranty
Three-Year Limited (Refer to Installation, Operation and Service Manual for Details)
Material Specification
Frame
Stamped Steel 12Ga
Stamped Steel 12Ga
Stamped Steel 12Ga
Welded Steel 3mm
Scroll and Inlet
Stamped Steel 16Ga
Cast Iron
Cast Iron
Welded Steel 3mm
Acoustic Boot
450°F Flexible Silicone
450°F Flexible Silicone
450°F Flexible Silicone
450°F Flexible Silicone
Weight (Lbs.)
62
112
112
170
Impeller Material
319 Cast Aluminum
319 Cast Aluminum
319 Cast Aluminum
Welded Steel
Impeller Size Dia. (In.) x Width (In.)
10 x 2 Radial
11 x 2-5/8 Radial
11 x 2-5/8 Radial
13-3/8 x 1-1/2 Radial
Paint
Electrostatic Epoxy Powder
?
Installation Code:
ROBERTS GORDON
®
products are to be installed only in accordance with local laws, codes and regulations, and only by a contractor qualified in the installation
and service of gas-fired heating equipment. This product is not for residential use.
Further Information:
Applications, engineering and detailed guidance on systems design, installation and product performance is available through ROBERTS GORDON
®
North American
independent distributors. Please contact us for any further information you may require, including the ROBERTS GORDON
®
Pump Installation, Operation and Service Manuals.
* Flow units are at sea level. For further detail, see CORAYVAC
®
Installation, Operation and Service manual.
** For combination of burners, see VANTAGE
® 
EV Installation, Operation and Service manual.
*** Note: For starter, see National Electric Code (NEC) Requirement for motors 1 HP and higher.
Roberts-Gordon
Roberts-Gordon Canada Inc.
1250 William Street
76 Main Street West, Unit 10
P.O. Box 44
Grimsby, Ontario L3M 1R6 Canada
Buffalo, NY 14240-0044 USA
Telephone: 905.945.5403 
Telephone: 716.852.4400
Fax: 905.945.0511
Fax: 716.852.0854
Toll Free: 800.828.7450
European Office:
Roberts-Gordon 
http://www.rg-inc.com
Telephone: +44(0) 1902 494425
Fax: +44(0) 1902 403200
Printed in U.S.A.
VPSNA
BB-5M0901RevD
©2003 Roberts-Gordon All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means – graphic, electronic, or
mechanical, including photocopying, recording, taping, or information storage and retrieval systems – without written permission of Roberts-Gordon.
Dimensional Data (In.)
A
B
C
D
E
F
G
EP 100
17
14.5
21
3.75
10
4
4
EP 201/203
17.75
17
18.75
3.25
10
4.5
4.5
EP 301
25.6
24.8
22.7
4.8
15.2
6
6