Procom ML100HPA User Manual

Page of 23
1 1
Figure 17 -   Control  Knob  In  The
OFF  Position
               Figure 18 - Pilot
OPERATING  YOUR   HEATER
Manual Control Models:
ML060HPA,ML100HPA
LIGHTING
INSTRUCTIONS
1 .    S T O P !     R e a d       t h e     s a f e t y
     information  on  the  side of
       heater.
2.  Check  that  gas  supply  to
       heater  is  on.
3.  Push  in  gas  control  knob
        slightly  and  turn clockwise  
        to    the   OFF   position.   ( see
        Figures  16 & 17)
4.   Wait five (5) minutes  to  clear
      out   any   air. Then   smell  for
       gas,  including  near  the  floor.
        If      you      smell     gas,    STOP!
       Follow   “B”     in     the     safety
        information  on  the  side of  the
       heater.  If   you   do   not   smell
       gas,  go  to  the  next  step.
5.    Push     in    gas   control   knob
      s l i g h t l y         a n d           t u r n
      counterclockwise    
      to
        “PILOT/IGN”   and  depress  for
         five(5) seconds
NOTE:   The  first  time  that  the     heater
is  operated  after   connecting  the
gas  supply ,  the      control  knob
should  be  depressed for  about  thirty
(30) seconds.  This will   allow  air   to
bleed   from  the  gas  system.
6.    With  control  knob  pressed  in,
       push  down  and   release   the
     ignitor button. This  will  light
       pilot.  If needed,  keep  pressing
      ignitor button until pilot lights.
7.   Keep  control  knob  depressed
    for  ten (10)  seconds  after
      lighting  pilot. If  pilot  goes  out,
       repeat  steps 5,6  and  7.
8.   To  select  the  desired  heating
       level,  partially   press  down  the
       control  knob  slightly  and  rotate
      counterclockwise         . Release
       the downward  pressure  on  the
        knob while  continuing to  turn  until
       the knob  locks at   the desired
       setting position.  Do not  operate
       between  locked  positions.
TO TURN OFF
GAS TO APPLIANCE
Shutting  Off  Heater
1.   Turn  control  knob  clockwise
         
  to  the  OFF  position.
2.     Turn  off  all   electric   power   to
       the  appliance  if  service  is  to
        be  performed.
Shutting Off  Burner  Only  (Pilot
Stays  Lit)
Turn control  knob  clockwise 
to  the  PILOT/IGN  position.
            CAUTION:   Do  not  try  to
adjust  heating  levels  by  using
the  equipment  shutoff  valve.
  Figure 20 -  Burner  Patterns
            WARNING:   When  running
h e a t e r , s e t     c o n t r o l   k n o b     a t
O N ,   L O W   o r     H I G H     l o c k e d
positions.(see Figure 19 & 20)
N e v e r   s e t   c o n t r o l   k n o b
between  locked positions. Poor
combustion and  higher  levels  of
carbon monoxide  may  result.
Slightly  press  in  control  knob  and
turn  counterclockwise               to  the
ON, LOW  or  HIGH  positions(see
Figure 19 & 20).
IMPORTANT:  Release  downward
pressure  while  turning  control  knob.
Control  knob  will  lock  at  the
desired  position.
   
TO  SELECT
             HEATING  LEVEL
1.     Remove  lower  front  panel (see
Figure 7 page 7).
2.    Follow   steps  through  5  under
        Lighting  Instructions.
3.    With  control    knob    pressed in,
        strike   match.   Hold   match   to
        pilot until  pilot  lights.
4.      Keep   control   knob   pressed   in
for 30 seconds  after  lighting pilot.
After 30  seconds, release control
knob.Follow step 8 under Lighting
Instuctions
 .
5.     Replace lower front panel.
MANUAL  LIGHTING
PROCEDURE
  Figure 19 -  Burner  Patterns
Figure 16 -    Control  Knob  In
The  OFF  Position
ML060HPA
ML100HPA