Dimplex CAL200 Leaflet

Page of 2
 
Calidou Electronic Panel Radiator
                                                                                   
Models
CAL075 / CAL100 / CAL150 / CAL200 
Dimensions and Specification 
Model Loading Length 
(A) Height Depth  X 
Z  Weight 
 
(kW) (mm) 
(mm) 
(mm) 
(mm) 
(mm) 
(mm) 
(kg) 
CAL075 0.75 
455 
604  142 140 87 228  17 
CAL100 1.0 
621  604 142 300 87 234  24 
CAL150 1.5 
870  604 142 400 226 242  33 
CAL200 2.0 
1202  604 142 700 227 275  47 
 
 
 
 
 
 
 
 
 
              THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE 
 
                                                                                                                                                              
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Installation and Operating Instructions   
Wall Mounting / Installation 
The heater should be positioned observing the minimum clearances 
stated around the heater. 
(see also ‘Electrical’ section) 
The wall bracket supplied with the heater must be used 
 
1.  Using a screwdriver, turn the latch in a clockwise direction to 
     unlatch the bracket, then remove it from the appliance (see Fig.1) 
2.  Mount the bracket on the wall using a minimum of 4 screws  
     (max diameter 6mm) making sure that it is the correct way up and 
     at the correct height. (see Fig.2) 
3.  Position the appliance on the bracket. 
4.  Re-latch the bracket turning the latch anti-clockwise. 
Electrical 
The wires in the mains lead are coloured in accordance with the following code: 
GREEN & YELLOW       EARTH 
BLUE NEUTRAL 
BROWN LIVE 
BLACK PILOT 
WIRE 
(See also ‘Pilot Wire Connection’) 
The heater is fitted with a length of flexible cable for connection to the fixed wiring of the 
premises through a suitable connection box positioned adjacent to the heater. 
The supply circuit to each heater must incorporate a double pole isolating switch having a 
contact separation of at least 3mm 
 
Pilot Wire Connection 
The BLACK control wire is designed to carry a signal from slot in or wall mounted Dimplex 
programmers. If, however a programmer is not being used, the pilot wire should be isolated in 
accordance with the current IEE Wiring Regulations. 
IMPORTANT - Do NOT connect the BLACK pilot wire to earth 
Care should be taken with the installation of the pilot wire(s) as when switching to background 
(set back) they become energised at 240V although only at a current of 1mA. 
In every case a suitable means of isolation must be provided for the pilot wire and marked to 
indicate that two sources of supply may be present at the heater. 
Where pilot wires are installed separately from the heater final sub-circuit they should be 
protected, double insulated and carry their own integral earth continuity conductor.  
Model A 
(mm  B 
(mm) 
CAL075 140 
228 
CAL100 300 
234 
CAL150 400 
242 
CAL200 700 
27 
IP24             
Issue 5   November 2004
 
General 
The Calidou radiator is designed to provide exceptional levels 
of comfort  with a combination of radiant and convected heat 
in both domestic and commercial applications. 
IMPORTANT SAFETY ADVICE 
 
• 
When using electrical appliances, basic precautions should always 
be followed to reduce the risk of fire, electrical shock, and injury to 
persons, including the following: 
• 
WARNING THE SURFACES OF THIS HEATER CAN BE HOT 
Momentary contact with any part of the heater should not cause 
injury. However, aged or infirm persons or young children should not 
be left unsupervised in the vicinity of the heater unless a suitable 
guard is fitted 
• 
IMPORTANT – If this heater is installed in a room containing a bath or 
shower, it should be so installed that switches and other controls 
cannot be touched by a person using a bath or shower – to comply 
with this requirement see ‘Lock the Control Cover’ section on page 2. 
• 
If you use this heater in conjunction with an external thermal control, 
a programme controller, a timer or any other device which switches 
the heat on automatically, observe all safety warnings AT ALL TIMES 
since a fire risk exists when the heater is accidentally covered or 
displaced 
• 
The installation of this product should be carried out by an electrician 
or competent person and be in strict accordance with the current IEE 
Wiring Regulations and relevant Building Regulations 
• 
This heater must not be mounted within 150mm of curtains and other 
combustible materials or 100mm from a shelf or overhang 
• 
NEVER cover or obstruct in any way the heat outlet slots at the top of 
the heater or the air inlet slots at the base of the heater 
• 
DO NOT cover the heater – Do not place material or garments on the 
heater or obstruct the air circulation around the heater  
• 
Before connecting the heater check that the supply voltage is the 
same as that stated on the heater 
• 
The heater must be installed in accordance with these instructions 
• 
The heater must be mounted using the wall bracket supplied. The 
heater should only be operated in the upright position 
• 
The heater should be positioned in accordance to the clearances 
stated in these instructions 
• 
DO NOT locate this heater immediately beneath a fixed socket outlet 
Fig.1 
 
Fig. 2
If the wall is a light partition or crumbling, then supporting legs 
are also needed  
(Part No. CAL0001). The heater MUST be fitted to the wall as 
well as having the supporting legs 
 
 
1. 
Place the legs under the heater 
2. 
Position the hinges into the grooves in the air inlet 
3. 
Unscrew the jacks, until they reach the floor