Homelite HHC100A User Manual

Page of 40
17
100577
13. Perform steps 1 through 6
(see page 16).
14. Place fine grade sandpaper
(600 grit) on flat surface.
Sand rotor lightly in “Figure
8” motion four times (see
Figure 30).
15. Reinstall insert and rotor.
16. Perform steps 10 through 12
(see page 16).
Gap Adjusting Screw
.003"/.004" (.076-.101 mm)
Gap Measured With
Feeler Gauge
Gap Adjusting Screw
Rotor
Blade
Figure 29 - Gap Adjusting Screw Locations
Model Size
35
100
150
Output Rating (Btu/Hr)
35,000
98,000
150,000
Fuel
Use Only Kerosene or No. 1 Fuel Oil
Fuel Tank Capacity (U.S. Gal./Liters)
3/11.3
9/34
13.5/51
Fuel Consumption (Gal. Per Hr/
Liters Per Hr)
.26/.98
.74/2.80
1.12/4.24
Nozzle Spray Angle
50°
60°
60°
Nozzle Spray Pattern
Solid Cone (All Models)
Electric Requirements
120 V/60 HZ (Same All Models)
Amperage (Normal Run)
1.7
3.2
4.4
Motor RPM
1725
3450
3450
Hot Air Output (CFM)
165
481
500
SPECIFICATIONS
Figure 30 - Sanding Rotor
Sandpaper