Dimplex DWF1146GP User Manual

Page of 12
 
5
  
Fireplace Installation 
Site Selection and Preparation
!
 NOTE: A 15 Amp, 120 Volt circuit is required. A 
dedicated circuit is preferred but not essential in 
all cases. A dedicated circuit will be required if, 
after installation, the circuit breaker trips or the 
fuse blows on a regular basis when the heater is 
operating. Additional appliances on the same circuit 
may exceed the current rating of the circuit breaker.
 CAUTION: 
When the heater is in use, this product 
draws a high, continuous electrical current. Not all 
electric receptacles are designed to work with high, 
continuous currents. If you plan on using this unit in 
an old, worn, or loose receptacle, or are unsure if 
the receptacle is suitable, please have it inspected 
by a qualified electrician prior to using this product.
 
WARNINg: Ensure the power cord is not installed 
so that it is pinched or against a sharp edge and 
ensure that the power cord is stored or secured to 
avoid tripping or snagging to reduce the risk of  
fire, electric shock or injury to persons.
  Construction and electrical outlet wiring must 
comply with local building codes and other 
applicable regulations to reduce the risk of  
fire, electric shock and injury to persons.
  Do not attempt to wire your own new outlets or 
circuits. To reduce the risk of fire, electric shock or 
injury to persons, always use a licensed electrician.
 
WARNINg: The supplied mounting bracket is 
designed for use with Dimplex wall mounted 
fireplaces only. Improper use, or use for purposes 
other than intended, may cause damage or injury.
Installation
 WARNINg: Failure to install the Sahara fireplace 
as instructed below may result in damage to the 
equipment and or may expose the user to the risk 
of fire, serious injury, illness or death.
 WARNINg: The Sahara fireplace requires the 
wall mounting bracket screws to be installed into a 
minimum of two wall studs (Figure 1).
Tools Required
#2 Phillips screwdriver
• 
Pencil
• 
Slot screwdriver
• 
Bubble level (supplied)
• 
Drill, and drill bits as required
• 
Approximate time: 30 minutes for installation
  Select an appropriate location to mount the unit 
on a wall, above an electrical outlet.  The bottom of the 
unit must be a minimum of 12 inches (31 cm) above 
the floor (mounting bracket 34 inches (86 cm) above 
the floor). Access to the electrical outlet must be 
maintained. Ensure the installation meets the national 
and state/provincial electrical codes.
!
 NOTE: It is recommended that the bottom of the 
unit not be mounted higher than 40 inches (102 cm) 
from the ground (mounting bracket no higher than 
62 inches (158 cm).
 WARNINg: Ensure the front of the installed 
unit will be at least three (3) feet (0.9 m) from 
combustible materials, such as furniture, pillows, 
bedding, papers, clothes, and curtains.
  The wall-mounting bracket must be mounted 
to at least two (2) wall studs. Studs should be 
accessed through two (2) wall-bracket holes in one 
of the following combinations:  A&F, B&D, or C&E  
(Figure 2).
Figure 1
12” - 40”
(31 cm - 102 cm)
34” - 62”
(86 cm - 158 cm)
 
 
Figure 2