Desa VTD-18N-BTB User Manual

Page of 26
111826-02F
For more information, visit www.desatech.com
16
TROUBLESHOOTING
Continued 
  WARNING: If you smell gas
•   Shut off gas supply.
•   Do not try to light any ap pli ance.
•   Do not touch any elec tri cal switch; do not use any phone in your 
build ing.
•   Immediately call your gas sup plier from a neighbor’s phone. Follow 
the gas sup pli er’s in struc tions.
•   If you cannot reach your gas sup plier, call the fi re de part ment.
IMPORTANT:
 Operating appliance where impurities in air exist may create odors. Cleaning 
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, 
etc., create fumes. These fumes may mix with combustion air and create odors. These 
odors will disappear over time.
POSSIBLE CAUSE
1.   Battery is not installed. Battery power is 
low
1.  Metal expanding while heating or con-
 tract ing  while  cooling
1.  Appliance burning vapors from paint, 
hair spray, glues, cleaners, chem i cals, 
new carpet, etc. (See 
IM POR TANT
 
state ment  above)
2.   Low fuel supply (propane/LP only)
3.   Gas leak. 
See Warn ing statement at 
top of page
1.   Not enough fresh air is available
2.   Low line pressure
3.   ODS/pilot is partially clogged
1.   Gas leak. 
See Warn ing statement at 
top of page
2.   Control valve or gas control defective
1.   Foreign matter be tween con trol valve and 
burner
2.   Gas leak. 
See Warn ing statement at 
top of page
REMEDY
1.  Replace 9-volt batteries in receiver and 
remote control
1.  This is common with most appliances. If 
noise is excessive, contact quali fi ed ser vice 
per son
1.   Open window to ventilate room. Stop us ing 
odor causing prod ucts while appliance is 
running
2.   Refi ll supply tank (propane/LP only)
3.   Locate and correct all leaks (see Check ing 
Gas Con nec tions, page 9)
1.   Open window and/or door for ven ti la tion
2.  Contact local natural or pro pane/LP gas 
company
3.   Clean ODS/pilot (see Cleaning and Main-
 te nance, page 13)
1.   Locate and correct all leaks (see Check ing 
Gas Con nec tions, page 9)
2.   Replace control valve or gas control
1.   Take apart gas tubing and remove for eign 
mat ter
2.   Locate and correct all leaks (see Check ing 
Gas Con nec tions, page 9)
OBSERVED PROBLEM
Remote does not function (Remote-Ready 
Models Only)
Appliance produces a click ing/tick ing  noise 
just after burners are lit or shut off
Appliance produces un wanted odors
Appliance shuts off in use (ODS operates)
Gas odor even when control knob is in OFF 
position
Gas odor during combustion
TROUBLESHOOTING