TROUBLESHOOTING
Continued
 WARNING: If you smell gas
•  Shut off gas supply.
•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any phone in your building.
•  Immediately call your gas supplier from a neighbor’s phone. Follow the 
gas supplier’s instructions.
•  If you cannot reach your gas supplier, call the fire department.
POSSIBLE CAUSE
1.  Metal expanding while heating or con-
tracting while cooling
1.  Residues from manufacturing processes 
and logs curing
1.  Gas leak. See Warning statement at 
top of page
2.  Control valve defective
1.  Foreign matter between control valve 
and burner
2.  Gas leak. See Warning statement at 
top of page
1.  Debris around burner air mixer
2.  Improper vent configuration
1.  Air holes at burner inlet blocked
2.  Burner flame holes blocked
3.  Improper venting or excessive blockage
4.  Excessive amounts of embers and pan 
material
OBSERVED PROBLEM
Fireplace produces a clicking/ticking noise 
just after burner is lit or shut off
Slight  smoke  or  odor  during  initial 
operation
Gas odor even when control knob is in OFF 
position
Gas odor during combustion
Glass soots
Dark residue on logs or inside of fireplace
REMEDY
1.  This is common with most fireplaces. 
If noise is excessive, contact qualified 
service person
1.  Problem will stop after a few hours of 
operation
1.  Locate and correct all leaks (see Check-
ing Gas Connections, page 19)
2.  Replace control valve
1.  Take apart gas tubing and remove for-
eign matter
2.  Locate and correct all leaks (see Check-
ing Gas Connections, page 19)
1.  Inspect the opening at the base of the 
burner  by  removing  log/grate  assem-
bly to see that it is NOT packed with 
any  type  of  material  [see  Installing 
Brick Liner Models BL36DA(SA) and 
BL36DHA(SA)] for log/grate removal
2.  Check vent configuration specifications 
(see  Venting  Installation  Instructions
page 7)
1.  Clean out air holes at burner inlets. Pe-
riodically repeat as needed
2.  Remove blockage
3.  Have the vent system inspected, includ-
ing the termination cap. Remove any 
restrictions or obstruction
4.  Clear excess embers until a minimum 
gap of 1/2" remains under the grate 
TROUBLESHOOTING