REFRACTORY
The  brick  refractory  on  the  interior  of  your 
fireplace (sides, back and bottom) is manu-
factured with a high quality cement mixture 
and reinforced with a wire mesh.
In a new fireplace or one with new refractory, 
allow refractory to cure for 24 hours. When 
building a fire, build a small one for the first 
3  or  4  fires.  The  refractory  is  subjected  to 
expansion and contraction from the heating 
and cooling of firebox during operation. It is 
acceptable to operate the fireplace with cracks 
of 1/64" wide.
If a crack should develop that is larger than 
the hairline crack described, take the following 
corrective measures:
1.  Patch  crack  with  a  refractory  patching 
cement  available  at  fireplace  shops  or 
hardware stores. The refractory must still 
be in one piece to patch.
2.  Replace  refractory  panel  (see  fireplace 
owner’s  manual).  DO  NOT  continue  to 
use your fireplace if your refractory has a 
crack that exceeds 1/64".
Refractories are available through your ser-
vice dealer.
GRATE 
If  grate  deteriorates  or  is  distorted,  replace 
with  DESA  Heating,  LLC  grate  designed 
for  your  fireplace  (see  fireplace  owner’s 
manual).
GLASS DOORS
Clean  glass  with  any  commercial  glass 
cleaner or soap and water. Do not use any 
abrasive material to clean glass. Do not clean 
glass with cool water if glass is still hot from 
use. Let doors dry completely before bulding 
the next fire.
TROUBlESHOOTING
clEaNING aND MaINTENaNcE
Continued
SMOKE
This fireplace has been designed to operate 
without  smoke  spillage  into  the  room  when 
installed and operated properly. In the event 
a smoking problem does occur, check for one 
of the following conditions:
1.  Outside  environmental  conditions  ad-
versely affecting draft.
2.  Lack of ventilation due to a tightly insu-
lated  house  could  prevent  the  fireplace 
from  drawing  properly.  If  this  happens, 
open  a  window  a  small  amount  while 
operating fireplace.
3.  Other appliances competing for available 
air in a tightly sealed home. These could 
be  heating  appliances,  kitchen  exhaust 
fans and bathroom exhaust fans.
4.  Relationship of your house to hills, trees 
and nearby taller buildings can affect wind 
conditions which can have a direct effect 
on your fireplace operation.
5,  Chimney  termination  not  installed  to 
proper height.
6.  Blockage of flue or termination cap.
7.  Flue and termination caked with creosote 
buildup.
8.  Grate too close to front of fireplace, not 
positioned behind smoke shelf. Position 
grate in designated area on brackets.
9.  Damper not in fully opened position.
10. Outside air damper not in opened posi-
tion.
11. Operating fireplace with partially opened 
doors.
12. Additional chimney pipe(s) may be neces-
sary under certain conditions. (Additional 
chimney  pipe  available  as  accessory 
item.)
IMPORTANT: For see-through and peninsula 
models, air currents in the room can cause 
some smoke spillage.
COLD AIR DRAFTS
In cold areas you must take special precau-
tions and follow COLD CLIMATE installation 
instructions in your owner’s manual.
If cold air drafts are present when your fire-
place is not in operation check the following:
1.  Air coming out of fireplace opening. Close 
damper.
2.  Air  near  sides  of  firebox  interior.  Close 
outside combustion air damper.
3.  Air coming in around sides of fireplace, 
between  fireplace  and  wall.  Make  sure 
fireplace frame has been caulked to en-
closure of frame.