Faults, causes and 
rectification  
Pump doesn’t run when power is 
switched on :
■ Check solar control unit for correct settings and tight wire 
   connections.
■ Check fuses.
■ Check pump voltage, refer to the pump rating plate for 
    requirements.
■ Close shut-off instruments upstream and downstream of 
   pump at high liquid temperatures and system pressures. 
    Allow pump to cool first.
■ Fully unscrew bleed screw and check ease of movement of 
  pump rotor by turning the slotted shaft end with a 
    screwdriver; use force to turn if necessary.
Motor blocked:
■  In the event of cavitation caused by insufficient inlet 
    pressure, increase primary system pressure within allowable 
     range.
■ Check speed setting.
Pump Noise:
If the fault cannot be rectified, please contact your nearest 
Lochinvar/TiSUN customer service representative.
 