CSB HR1224W Leaflet

Page of 2
Cells Per Unit
6
Voltage Per Unit
12
Capacity
24W @ 15min-rate to 1.67V per cell @25 (77 )
Weight
Approx.
1.95 kg(4.3 lbs)
Maximum Discharge Current
100A/130A(5sec)
Internal Resistance
Approx. 21 m
Operating Temperature Range
Nominal Operating Temperature Range
25
3 (77
5 )
Float Charging Voltage
13.5 to 13.8 VDC/unit Average at 25 (77 )
Recommended Maximum Charging
2.4A
Current Limit
Equalization and Cycle Service
14.4 to 15.0 VDC/unit Average at 25 (77 )
Self Discharge
CSB Batteries can be stored for more than 6 months at
25 (77 ). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
Terminal
F1/F2-Faston Tab187/250
Container Material
ABS(UL 94-HB/File E50263)*Flammability resistance of
(UL 94-V0/File E88637) can be available upon request.
Discharge: -15 ~50 ( 5 ~122 )
Charge: -15
~40 (  5 ~104 )
Storage: -15 ~40 ( 5 ~104 )
Constant Power Discharge Characteristics Unit:W (25
,77 )
Constant Current Discharge Characteristics Unit:A (25
,77 )
HR 1224W
12V 24W
Specification
Powered by
HR 1224W is specially designed for high efficient
discharge application. Its characteristics are high energy
density, small footprint and high discharge efficiency. It can
be used for more than 260 cycles at 100% discharge in cycle
service, up to 5 years in standby service.
Width (W)
Dimensions : 
Unit: mm (inch)
Overall Height (H)
Container height (h)
Length (L)
98.3±1 (3.87±0.04)
94±1 (3.7±0.04)
151±2 (5.94±0.08)
51±1.2 (2.01±0.05)
F.V/Time
2MIN
4MIN
6MIN
8MIN
10MIN
15MIN
20MIN
30MIN
60MIN
90MIN
1.60V
47.5
33.0
26.1
22.0
18.9
14.0
11.0
7.95
4.29
3.43
1.67V
44.1
31.1
24.7
21.0
18.0
13.5
10.6
7.76
4.20
3.34
1.70V
42.7
30.3
24.0
20.5
17.6
13.2
10.5
7.67
4.15
3.30
1.75V
40.5
28.8
23.0
19.8
17.0
12.8
10.2
7.56
4.10
3.26
1.80V
38.4
27.4
22.2
19.1
16.4
12.5
10.0
7.49
4.06
3.22
1.85V
36.4
26.0
21.3
18.5
16.0
12.1
9.84
7.44
4.04
3.19
F.V/Time
2MIN
4MIN
6MIN
8MIN
10MIN
15MIN
20MIN
30MIN
60MIN
90MIN
1.60V
570
396
313
264
228
168
132
95.4
51.5
41.2
1.67V
529
373
297
251
217
162
128
92.9
50.3
40.2
1.70V
512
363
289
246
212
159
126
92.1
49.9
39.7
1.75V
486
346
277
238
204
154
123
90.8
49.3
39.2
1.80V
461
329
266
229
197
149
121
89.9
48.8
38.8
1.85V
437
314
256
219
187
144
119
89.2
48.5
38.6
RA0911
CSB-manufactured
VRLA 
batteries are UL-
recognized components
under UL924 and UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
 
(http://www.csb-battery.com) 
by TUV CERT according to ISO 9001,ISO 14001.
The system of manufacturer was certified