Dayton 3VG79B User Manual

Page of 16
Operating Instructions & Parts Manual
3VG79B
Dayton Portable Forced
Air Heater
Description
Dayton Model 3VG79B is a 200,000 Btu/Hr heater. This heater uses only Kerosene
or No. 1 fuel oil for combustion and electricity to run the motor. It is primarily
intended for indoor and outdoor temporary heating of well-ventilated buildings
under construction, alteration, or repair. It may be used in agricultural, industrial,
and commercial environments.
®
Form 5S4068
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Unpacking
1. Remove all packing items supplied
with heater for shipment.
2. Remove all items from carton.
3. Check items for any shipping
damage. If heater is damaged,
promptly inform dealer where you
bought heater.
Figure 1 - Model 3VG79B
ARL LOGO
G 004
®
Amperage
Electrical Input
(during normal run)
120 Volt/60 Hertz
3.6
ELECTRICAL SPECIFICATIONS
GENERAL SPECIFICATIONS
Output
Hot Air Output
Fuel Tank Capacity
Fuel Consumption
Rating Btu
(CFM Approx)
Fuel
(U.S. Gallons)
(U.S. Gallons/Hr.)
200,000
600
Kerosene or No. 1 fuel oil
13.5
1.4
Air Pump
Heater Weight
Heater Weight
Motor RPM
Pressure (psi)
(Pounds - with fuel)
(Pounds - without fuel)
3400
6.2
77
66
Version B - For Reduction 
G016.J
®
Printed in U.S.A.
03430
0700/256/VCPVP