SAFETy INFORMATION
Continued
1.  This appliance is only for use with the type 
of gas indicated on the rating plate. This ap-
pliance is not convertible for use with other 
gases. 
2.  Do not place propane/LP supply tank(s) in-
side any structure. Locate propane/LP supply 
tank(s) outdoors (propane/LP units only).
3.  If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use 
any phone in your building
• immediately call your gas supplier from a 
neighbor’s phone. Follow the gas supplier’s 
instructions
• if you cannot reach your gas supplier, call 
the fire department
4.  This heater shall not be installed in a bedroom 
or bathroom, unless installed as a vented appli-
ance. See Installing Damper Clamp Accessory 
for Vented Operation, page 12.
5.  Before  installing  in  a  solid  fuel  burning 
fireplace, the chimney flue and firebox must 
be cleaned of soot, creosote, ashes and loose 
paint by a qualified chimney cleaner. Creosote 
will ignite if highly heated. A dirty chimney 
flue may create and distribute soot within 
the house. Inspect chimney flue for damage. 
If damaged, repair flue and firebox before 
operating heater.
6.  Do not burn solid-fuel in a masonry or UL127 
factory-built fireplace in which a vent-free 
room heater is installed.
7.  If fireplace has glass doors, never operate this 
heater with glass doors closed. If you operate 
heater with doors closed, heat buildup inside 
fireplace will cause glass to burst. Make sure 
there are no obstructions across openings of 
fireplace.
8.  To prevent the creation of soot, follow the 
instructions in Cleaning and Maintenance
page 23.
9.  Before using furniture polish, wax, carpet 
cleaner or similar products, turn heater off. If 
heated, the vapors from these products may 
create a white powder residue within burner 
box or on adjacent walls and furniture.
10.  This heater needs fresh, outside air ventilation 
to run properly. This heater has an Oxygen 
Depletion Sensing (ODS) safety shutoff sys-
tem. The ODS shuts down the heater if enough 
fresh air is not available. See Air for Combus-
tion and Ventilation, page 6. If heater keeps 
shutting off, see Troubleshooting, page 25.
11.  Do not run heater
• where flammable liquids or vapors are used 
or stored
• under dusty conditions
12.  Do not use this heater to cook food or burn 
paper or other objects.
13.  Do not use heater if any part has been exposed 
to or under water. Immediately call a qualified 
service technician to inspect the room heater 
and to replace any part of the control system and 
any gas control which has been under water. 
14.  Do not operate heater if any log is broken. Do 
not operate heater if a log is chipped (dime-
sized or larger). 
15.  Turn heater off and let cool before servicing, 
installing or repairing. Make sure the selector 
switch is in the OFF position. Only a qualified 
service person should install, service or repair 
heater.
16.  Make sure the selector switch is in the OFF 
position when you are away from home for 
long periods of time. 
17.  Remote-ready heaters must not be connected 
to any external electrical source.
18.  Operating heater above elevations of 4,500 
feet may cause pilot outage.
19.  To prevent performance problems, do not 
use propane/LP fuel tank of less than 100 lb. 
capacity (propane/LP units only).
20.  Provide  adequate  clearances  around  air 
openings.