Desa HDVF3018N User Manual

Page of 28
www.desatech.com
119421-01A
15
INSTALLATION 
Continued
Test Pressures Equal To or Less Than 
1/2 PSIG (3.5 kPa)
1.  Close equipment shutoff valve (see Figure 15).
2.  Pressurize supply piping system by either 
opening propane/LP supply tank valve for 
propane/LP gas or opening main gas valve 
located on or near gas meter for natural gas 
or using compressed air.
3.  Check all joints from gas meter to equipment 
shutoff valve for natural gas or propane/LP 
supply to equipment shutoff valve for pro-
pane/LP  (see  Figures  16  and  17).  Apply 
noncorrosive leak detection fluid to all joints. 
Bubbles forming show a leak. 
4.  Correct all leaks at once.
Figure 15 - Equipment Shutoff Valve
Figure 16 - Checking Gas Joints 
(Propane/LP Gas Models)
Equipment 
Shutoff Valve
Propane/LP 
Supply Tank
Control Valve Location
Figure 17 - Checking Gas Joints (Natural 
Gas Models)
Gas Meter
Equipment Shutoff Valve
Control Valve Location
Equipment 
Shutoff 
Valve
Open
Closed
pRESSURE TESTING HEATER GAS 
CONNECTIONS
1.  Open equipment shutoff valve (see Figure 15).
2.  Open main gas valve located on or near gas 
meter for natural gas or open propane/LP 
supply tank valve.
3.  Make sure control knob of heater is in the OFF 
position.
4.  Check all joints from equipment shutoff valve 
to control valve (see Figures 16 and 17). Apply 
noncorrosive leak detection fluid to all joints. 
Bubbles forming show a leak.
5.  Correct all leaks at once.
6.  Light heater (see Operating Heater, page 17). 
Check all other internal joints for leaks.
7.  Turn off heater (see To Turn Off Gas to Appli-
ance, page 18).
INSTALLING LOGS
  CAUTION:  After  installa-
tion and periodically thereafter, 
check  to  ensure  that  no  flame 
comes in contact with any log. 
With the heater set to HI, check 
to see if flames contact any log. If 
so, reposition logs according to 
the log installation instructions 
in this manual. Flames contact-
ing logs will create soot.
 WARNING: Failure to posi-
tion  the  parts  in  accordance 
with  these  diagrams  or  failure 
to  use  only  parts  specifically 
approved with this heater may 
result  in  property  damage  or 
personal injury.
Each log is marked with a number. These numbers 
will help you identify the log when installing. It 
is very important to install these logs exactly as 
instructed. Do not modify logs. Only use logs 
supplied with heater.
1.  Place front log (#1) on grate fingers. Make sure 
front log rests firmly between grate fingers and 
grate base (see Figure 18, page 16).
2.  Place base of middle log (#2) in U-shaped 
slots of grate base. The large cutout on bottom 
right of middle log should fit over burner (see 
Figure 19, page 16). Make sure front of middle 
log is resting on tabs of grate base.