Figure 22 - Control Knob and Ignitor 
Button Location
Ignitor Button
Control Knob
Figure 23 - Pilot
Thermocouple
Pilot Burner
Ignitor
Electrode
 VARIABLE CONTROL 
OpERATION
The variable control valve can be set to any 
heat setting and flame height desired, by simply 
turning the control knob until that setting is 
attained. Even the lowest setting provides re-
alistic, dancing yellow flames. Selecting higher 
settings produces greater heat output. This 
results in increased heating comfort.
 CAUTION: Do not try to ad-
just heating levels by using the 
equipment shutoff valve.
 TO TURN OFF GAS 
TO AppLIANCE 
Shutting Off Heater
1.  Press in and turn control knob clockwise 
 to the HI position.
2.  Turn control knob clockwise 
 to the 
pilot position.
3.  Press in control knob and turn clockwise 
 to the OFF position.
Shutting Off Burner(s) Only (pilot stays lit)
1.  Turn control knob clockwise 
 to the 
HI position.
2.  Press in and turn control knob clockwise 
 to the pilot position. 
 MANUAL LIGHTING 
pROCEDURE
1.  Follow steps 1 through 5 under Lighting 
Instructions, page 17.
2.  Depress control knob and light pilot with 
match.
3.  Keep control knob pressed in for 30 seconds 
after lighting pilot. After 30 seconds, release 
control knob. Now follow step 8, under 
Lighting Instructions, column 1. 
5.  Slightly press and turn control knob coun-
terclockwise 
 to the PILOT position. 
Press in control knob for five (5) seconds 
(see Figure 22). 
  Note: You may be running this heater for 
the first time after hooking up to gas sup-
ply. If so, the control knob may need to be 
pressed in for 30 seconds or more. This will 
allow air to bleed from the gas system.
6.  With control knob pressed in, press and 
release ignitor button. This will light pilot. 
The  pilot  is  attached  to  the  burner.  If 
needed, keep pressing ignitor button until 
pilot lights.
  Note: If pilot does not stay lit, contact a 
qualified service person or gas supplier for 
repairs. Until repairs are made, light pilot 
with match. To light pilot with match, see 
Manual Lighting Procedure.
7.  Keep control knob pressed in for 30 seconds 
after lighting pilot. After 30 seconds, release 
control knob.
  Note:  If  pilot  goes  out,  repeat  steps  3 
through 7. If control knob does not pop out 
when released, contact a qualified service 
person or gas supplier for repairs.
8.  Slightly  press  and  turn  control  knob 
counterclockwise 
 to desired heat-
ing level. The burner(s) should light. Set 
control knob to any heat level between HI 
and LO.
  WARNING:  Do  not  operate 
heater  between  PILOT  and  HI 
positions.
OPERATING HEATER