oPeRaTIoN
Continued
Note: The thermostat sensing bulb measures 
the temperature of air near the heater cabinet. 
This  may  not  always  agree  with  room  tem-
perature (depending on housing construction, 
installation location, room size, open air tem-
peratures, etc.). Frequent use of your heater will 
let you determine your own comfort levels.
MANUAL LIGHTING 
PROCEDURE
1.  Remove front panel (see Figure 7, page 9).
2.  Follow steps 1 through 7 under Lighting 
Instructions, page 15.
3.  With control knob pressed in, strike match. 
Hold match to pilot until pilot lights.
4.  Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds, 
release control knob. Now follow step 9, 
under Lighting Instructions, page 15.
5.  Replace front panel.
BLOWER 
OPERATION
 WARNING: Blower accessory 
must be grounded. Blower comes 
with  a  three-prong,  grounding 
plug as shown in Figure 22. The 
plug is your protection against 
electrical  shock.  Plug  it  into  a 
standard, three-hole, grounded, 
outlet.  If  cord  needs  replacing, 
use  only  a  cord  with  a  three-
prong, grounding plug.
  CAUTION:  Label  all  wires 
prior  to  disconnection  when 
servicing controls. Wiring errors 
can cause improper and danger-
ous operation.
 CAUTION: Do not plug power 
cord  into  electrical  outlet  until 
installation is complete.
Figure 21 - Pilot (actual pilot may vary)
 WARNING: Always operate 
manual  control  heaters  at  the 
locked  positions.  Operation 
between  these  positions  may 
create a possible health hazard 
if  used  in  a  poorly  ventilated 
room. Read owner’s manual for 
complete instructions.
 CAUTION: Do not try to ad-
just heating levels by using the 
equipment shutoff valve.
TO TURN OFF GAS 
TO APPLIANCE
Shutting Off Heater
1.  Turn control knob clockwise 
 to the 
OFF position.
2.  Turn off all electric power to the appliance 
if service is to be performed.
3.  Close equipment shutoff valve (see Figure 
16, page 14).
THERMOSTAT CONTROL 
OPERATION
The  thermostatic  control  used  on  these 
models  differs  from  standard  thermostats. 
Standard thermostats simply turn on and off 
the burner. The thermostat used on this heater 
senses the room temperature. The thermostat 
adjusts the amount of gas flow to the burner. 
This increases or decreases the burner flame 
height. At  times  the  room  may  exceed  the 
set  temperature.  If  so,  the  burner  will  shut 
off. The burner will cycle back on when room 
temperature drops below the set temperature. 
The control knob can be set to any heat level 
between 1 and 5. Selecting the 5 setting will 
cause the burner to remain fully on without 
modulating down in most cases.
Thermocouple
Ignitor Electrode
Pilot Burner
Grounded 
Outlet
Figure 22 - Grounding Plug