INSTALLATION
 WARNING: Review and un-
derstand  the  warnings  in  the 
Safety Information section, page 
2. They are needed to safely op-
erate this heater. Follow all local 
codes when using this heater.
 WARNING: Test all gas piping 
and connections for leaks after 
installing or servicing. Never use 
an open flame to check for a leak. 
Apply a mixture of liquid soap 
and water to all joints. Bubbles 
forming show a leak. Correct all 
leaks at once.
1.  Provide propane/LP supply system (see Pro-
pane/LP Supply, page 4).
2.  Connect POL fitting on hose/regulator assem-
bly to propane/LP tank(s). Turn POL fitting 
counterclockwise into threads on tank. Tighten 
firmly using a wrench. IMPORTANT: Tighten 
regulator with black adjustment knob point-
ing down. Pointing adjustment knob down 
protects regulator from weather damage.
3.  Connect hose to inlet connector. Tighten firmly 
using a wrench.
 
IMPORTANT:
  Extra  hose  or  piping  may 
be used if needed. Install extra hose or pip-
ing  between  hose/regulator  assembly  and 
propane/LP tank. You must use the regulator 
supplied with the heater.
4.  Open propane/LP supply valve on propane/LP 
tank(s) slowly. Note: If not opened slowly, ex-
cess-flow check valve on propane/LP tank will 
stop gas flow. If this happens, you may hear a 
click inside the regulator assembly. To reset 
the excess flow check valve, close propane/LP 
supply valve and open again slowly.
OPERATION
 WARNING: Review and un-
derstand  the  warnings  in  the 
Safety Information section, page 
2. They are needed to safely op-
erate this heater. Follow all local 
codes when using this heater.
TO START HEATER
1.  Follow all installation, ventilation and safety 
information.
2.  Locate  heater  on  stable  and  level  surface. 
Make sure strong drafts do not blow into front 
or rear of heater.
3.  Plug power cord of heater into a three-prong, 
grounded extension cord. Extension cord must 
be at least six feet long. Extension cord must 
be UL listed.
 
Extension Cord Size Requirement
 
Up  to  50  feet  (15  m)  long,  use  18 AWG 
rated cord.
 
51 to 100 feet (15.5 to 30.5 m) long, use 16 
AWG rated cord.
 
101 to 200 feet (30.78 to 61 m) long, use 14 
AWG rated cord.
4.  Plug extension cord into a 120 volt/60 hertz, 
three-hole, grounded outlet.
Propane/LP 
Tank
Supply 
Valve
Hose
POL Fitting
Regulator
Adjustment Knob 
(pointing down)
Figure 3 - Regulator With Adjustment 
Knob Pointing Down
Figure 4 - Hose and Inlet Connector
Hose
Inlet Connector
5.  Adjust regulator between 7 and 20 psig. Note: 
Higher regulator setting will allow heater to 
produce more heat.
6.  Check all connections for leaks.
7.  Close propane/LP supply valve.
  WARNING:  Do  not  adjust 
regulator below 7 psig or above 
20  psig.  Heater  may  not  run 
properly.