Thermo Products THJF18 THRU 60 Data Sheet

Page of 2
TABULAR DATA SHEET
Outdoor Split System Heat Pump 1.5 Thru 5 Tons
MODELS: THJF18* THRU 60
14.5 SEER – R-410A, 1 PHASE
All dimensions are in inches. They are subject to change without notice.
Certified dimensions will be provided upon request.
Physical and Electrical Data
MODEL
THJF18
S41S3
THJF24
S41S3
THJF30
S41S3
THJF36
S41S3
THJF42
S41S3
THJF48
S41S3
THJF60
S41S3
Unit Supply Voltage
208-230V, 1
 60Hz
Normal Voltage Range 
1
187  to 252
Minimum Circuit Ampacity
11.9
17.6
17.3
23.7
26.1
28.8
35.3
Max. Overcurrent Device Amps 
2
20
30
30
40
45
50
60
Min. Overcurrent Device Amps 
3
15
20
20
25
30
30
40
Compressor Type 
Scroll
Scroll
Scroll
Scroll
Scroll
Scroll
2-Stage Scroll
Compressor 
Amps
Rated Load
9.0
13.4
12.8
17.9
19.8
28.8
35.3
Locked Rotor
48.0
58.3
64.0
96.7
115.0
115.0
118.0
Crankcase Heater
No
No
No
No
No
No
No
Factory External Discharge Muffler
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Factory  External  Check  Valve
No
No
No
No
No
No
No
HS Kit Required with TXV 
4
No
No
No
No
No
No
No
Fan Motor Amps
Rated Load
0.7
0.8
1.3
1.3
1.3
1.3
1.3
Fan Diameter Inches
24
22
24
24
24
24
24
Fan Motor
Rated HP
1/10
1/8
1/4
1/4
1/4
1/4
1/4
Nominal RPM
825
1075
850
850
850
850
850
Nominal CFM
2000
2000
3900
3900
3900
3800
3800
Coil
Face Area Sq. Ft.
15.72
19.17
23.58
23.58
23.58
23.58
23.58
Rows  Deep
1
1
1
1
1
2
2
Fin / Inches
22
22
22
22
22
18
18
Liquid Line Set OD (Field Installed)
3/8
3/8
3/8
3/8
3/8
3/8
3/8
Vapor Line Set OD (Field Installed)
3/4
3/4
3/4
3/4
7/8
7/8
1-1/8
Unit Charge (Lbs. - Oz.) 
5
6 - 15
7 - 14
9 - 14
10 - 9
10 - 14
14 - 2
14 - 2
Charge Per Foot, Oz.
0.62
0.62
0.62
0.62
0.67
0.67
0.75
Operating Weight Lbs.
145
145
176
193
198
248
290
1. Rated in accordance with ANSI/AHRI Standard 110-2002, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model. 
5. The Unit Charge is correct for the outdoor unit, matched indoor coil, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, 
add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
B
C
A
Unit
Model
Dimensions
(Inches)
Refrigerant Connection
Service Valve Size
A
1
1. Including Fan Guard.
B
C
Liquid
Vapor
18
28
34
34
3/8”
3/4”
24
40
29
29
30
40
34
34
36
40
34
34
42
40
34
34
7/8”
48
40
34
34
60
40
34
34
MAC-222 
ECN 5287-MA 121005