Dimplex LI MS User Manual

Page of 4
TECHNICAL DATA
EQUIPMENT DATA for air source heat pumps for heating purposes
1
TYPE AND COMMERCIAL DESCRIPTIONS
LI11MS
LI16AS 
2 MODEL 
2.1
Enclosure type acc to EN 60 529 for compact unit or heating element IP 21
IP 21
IP 21 
2.2
Installation site
Indoors
Indoors 
3
PERFORMANCE DATA
3.1
Operating temperature limits:
Heating water supply / return 
3)
°C / °C
Max. 55 / min. 18
Max. 55 / min. 18 
Air
°C
-20 to +35
-20 to +35 
3.2
Heating water temperature difference at A2 / W35
7.5
7.5 
3.3
Heating capacity/coeff.of perform.
at A-7 / W35 
1)
kW/---
7.6 / 2.9
9.8 / 2.6 
at A2 / W35 
1)
kW/---
9.1 / 3.4
12.2 / 3.2 
at A2 / W50 
1)
kW/---
9.0 / 2.5
11.5 / 2.4
at A7 / W35 
1)
kW/---
10.9 / 4.1
15.4 / 3.7
at A10 / W35 
1)
kW/---
12.0 / 4.6
16.1 / 3.8 
3.4
Sound power level of unit / outside
dB(A)
55 / 61
57 / 62 
3.5
Heating water flow rate at internal pressure difference
m
3
/h/Pa
1.0 / 3000
1.4 / 4500 
3.6
Air flow rate at external static pressure difference
m
3
/h/Pa
4200 / 0
5200 / 0
m
3
/h/Pa
2500 / 25
4000 / 25
3.7
Refrigerant: total charge weight
Type / kg
R404A / 2.5
R404A / 3.1 
4
DIMENSIONS, CONNECTIONS AND WEIGHT
4.1
Equipment dimensions
H x W x L mm
1360 x 750 x 850
1570 x 750 x 850 
4.2
Equipment connections for heating system
inches
G 1” ext. thread
G 1” ext. thread 
4.3
Air duct inlet and outlet (min. inside dimensions)
L x W mm
500 x 500
570 x 570
4.4
Weight of transport unit(s) incl. packaging
kg
200
235
5
ELECTRICAL CONNECTIONS
5.1
Nominal voltage; fusing
V/A
230 / 25
400 / 20
5.2
Nominal power consumption 
1)
A2 W35
kW
2.65
3.81 
5.3
Starting current with soft starter
A
38
25
5.4
Nominal current A2 W35/cos
A /---
14.4 / 0.8
6.9 / 0.8
6
COMPLIES WITH EUROPEAN SAFETY REGULATIONS
4)
4)
7
OTHER DESIGN CHARACTERISTICS 
7.1
Defrosting
Automatic
Automatic 
Type of defrosting
Cycle reversal
Cycle reversal 
Defrost pan available
Yes (heated)
Yes (heated) 
7.2
Heating water inside unit protected against freezing 
2)
Yes
Yes 
7.3
Performance settings
1
1
7.4
Controller internal / external
External
External 
1)
This data characterises the size and performance capacity of the system. For economic and energy consumption reasons, additional factors such as 
defrosting behaviour, bivalence point and control need to be taken into consideration. Abbreviations have the following meaning e.g. A2 / W55: heat source 
temperature 2°C and heating water supply temperature 55°C.
2)
The heat circulating pump and the controller of the heat pump must be on standby at all times.
3)
See operating limits diagram.
4)
See CE Declaration of Comformity.
Subject to technical modifications