3. Outline of schedule setting and operation 
3-1.  Outline of setting 
The schedule is set with this controller using the following procedures. 
1. Setting of current time and day 
2. Setting of program 
Set the schedule pattern. (Up to nine types of operations patterns with 16 operations in each 
pattern can be set.) 
[Setting example] 
Set details 
 
Pattern Operation Set time 
ON/OFF Mode Set 
temp.
Operation 
prohibit 
 
1  
8:15 
ON 
Cool 29°C
Room temp. 
adjustment 
2 10:00 
OFF - -  ON/OFF 
Set the time to start schedule 
operation, and the details of the 
operation. 
3 10:15 
ON - 
27°C
Enable  
4 12:00 
OFF - -  ON/OFF 
5 13:00 
ON - 
25°C
Room temp. 
adjustment 
6 17:00 
OFF - -  Enable 
: : : 
:  : 
16 21:00 
OFF - -  ON/OFF 
With operation 1, cooling with the air 
conditioner is started at 08:15, 
operation is continued at 29°C, and 
adjustment of the room temperature 
with the local remote controller is 
prohibited. 
1  
9:00 
ON - 
27°C
Room temp. 
adjustment 
 
: : : 
:  :  
16 22:00 
OFF - -  ON/OFF 
 
: : : : 
::  :  
1  
8:30 
ON 
Heat 22°C
Room temp. 
adjustment 
 
: : : 
:  :  
16 21:30 
OFF - -  ON/OFF 
 
 
3. Setting of weekly program   
Set the schedule pattern set in step 2 in day-units for each group. 
[Setting example] 
Day 
Group 
Sun. Mon. Tue. Wed. Thu.  Fri.  Sat. 
 
Pattern 1  Pattern 2  Pattern 2 Pattern 2 Pattern 2 Pattern 2 Pattern 1
No setting  Pattern 3  Pattern 3 Pattern 4 Pattern 4 Pattern 5 Pattern 6
 
 
 
 
 
 
 
50 
Pattern 9  Pattern 7  Pattern 7 Pattern 8 Pattern 8 No setting Pattern 9
 
 
 
 
 
 
 
 
Pattern 1 is used for the 
schedule operation on 
Sunday in group 1. 
Schedule operation is not 
carried out on Sunday in 
group 2.