FEATURES
1. COMPACT DESIGN
The PK series models have been downsized and now require such minimal wall space that they can even be installed
above windows. For the PKH18/24FK, 13in of wall space between the ceiling and the window allows “above window”
installation (14.5in for the PKH30/36FK)
2. A FURTHER REFINEMENT OF COMFORT WITH NOISE SUPPRESSION
Remarkably low-noise operation has been achieved through the development of a “near-silent” fan and a design which
minimizes airflow resistance.
3. AUTO FLAP SHUTTER
With a simple flick of the OFF switch the air outlet can be closed off with a shutter. The shutter also functions as a flap
during operation to adjust the air flow angle, with “Auto Angle 1” securing a comfortable air flow.
4. INSTALLATION : FAST AND ENDLESSLY ADAPTABLE
(1) External piping
An external piping connection of 24in and a very light body promote trouble-free installation for PKH18FK.
(2) Multi-directional piping
Multi directional drain and refrigerant piping rodically improves flexibility in selecting installation layouts. PKH18FK drain
piping can be installed in 5 directions, while PKH30/36FK models boast refrigerant piping in 4 directions and drain piping
in 2 directions.
(3) Back plate installation guide
The back plate installation guide gives clear instructions on installation positions. The enlarged back plate secures the
unit firmly to the wall, while the support piece which lifts the unit makes left side piping work much easier.
(4) Front power supply box
The front power supply box allows electrical wiring work to be performed easily even after the indoor unit has been fully
installed. All the screws for the indoor unit  can be tightened from the front side thus ensuring smooth installation.
(only for PKH18/24FK)
(5) Easily removable filter
The presence of thumbscrews on the filters means that the filters can be quickly and smoothly removed.
(only for PKH30/36FK)
MITSUBISHI ELECTRIC
-CENTRALLY CONTROLLED-
  STAND BY
   DEFROST
ON
CHECK DRY
COOL
HEAT
CHECK
SET TEMP
TIMER OFF
AUTO STOP
AUTO START
F
HR
F
LOW HIGH
AUTO RETURN
CHECK TEST RUN
POWER
ON/OFF
HEAT
SET
TEMPERATURE
AUTO
COOL/DRY
COOLER
WARMER
TIMER
MODE
HOURS
FAN SPEED LOW/HIOGH
AIR
DISCHARGE
UP/DOWN SWING STOP
CHECK
TEST RUN
Indoor unit
Remote controller
Models
Cooling capacity / Heating capacity
SEER
PKH18FK
18,000 / 18,600 [25,100] Btu/h
11.1
PKH24FK
24,000 / 25,000 [31,500] Btu/h
10.2
PKH30FK
30,000 / 33,000 [40,500] Btu/h
10.6
PKH36FK
34,200 / 38,000 [45,500] Btu/h
10.5
PUH24EK
Outdoor unit
OC120--1.qxp  24/6/97 12:20 AM  Page 2