Mitsubishi Electronics SRK507J-S User Manual

Page of 34
-
  
-
 '10 • SR-T-091D
1. SPECIFICATIONS
        (1)   Wall mounted type (SRK)
B
RWA000Z225
Model
Item
SRK50ZJ-S
Indoor unit 
SRK50ZJ-S
Outdoor unit 
SRC50ZJ-S
Cooling capacity (1)
W
5000 (1600 (Min.)~5500 (Max.))
Heating capacity (1)
W
5800 (1600 (Min.)~6600 (Max.)) 
Power supply
1 Phase, 220~240 V, 50Hz
Operation
  data (1)
Power 
consumption
Cooling
kW
1.55 (0.40~2.20)
Heating
1.59 (0.42~2.10)
Running 
current
Cooling
A
7.1 / 6.8 / 6.5  (220/ 230/ 240 V)
Heating
7.3 / 7.0 / 6.7  (220/ 230/ 240 V)
Inrush current
7.3 / 7.0 / 6.7  (220/ 230/ 240 V)
COP
Cooling
3.23
Heating
3.65
Noise
level
Cooling
Sound level
dB(A)
Hi : 46  Me : 37  Lo : 26
51
Power level
dB
61
61
Heating
Sound level
dB(A)
Hi : 45  Me : 37  Lo : 31
53
Power level
dB
61
63
Exterior dimensions (Height x Width x Depth)
mm
294 x 798 x 229
640 x 800 (+71) x 290
Exterior appearance
  (Munsell color)
Fine snow
( 8.0Y 9.3/0.1 ) near equivalent 
Stucco white
( 4.2Y 7.5/1.1 ) near equivalent 
Net weight
kg
9.5
42
Refrigerant
  equipment
Compressor type & Q'ty
5RS132XAB21 (Rotary type) x 1
  Motor (Starting method)
kW
0.90 (Line starting)
Refrigerant oil
0.37 (FV50S)
Refrigerant (4)
kg
R410A 1.35 (Pre-Charged up to the piping length of 15m)
Heat exchanger
Louver fins & inner grooved tubing
M fins & inner grooved tubing
Refrigerant control
Capillary tubes + Electronic expansion valve
Deice control
Microcomputer control
Air handling
  equipment
Fan type & Q'ty
Tangential fan x 1
Propeller fan x 1
  Motor
W
38
34
Air flow 
Cooling
CMM
 Hi : 11.3  Me : 7.8  Lo : 5.3
36.0
Heating
 Hi : 13.5  Me : 10.2  Lo : 7.5
36.0
Fresh air intake
Not possible
Air filter, Quality / Quantity
 Polypropylene net (washable) x 2 
Shock & vibration absorber
Cushion rubber (for compressor)
Electric heater
Operation
  control
Operation switch
Wireless-Remote control
Room temperature control
Microcomputer thermostat
Operation Display
RUN : Green, TIMER : Yellow, HI POWER : Green, 3D AUTO : Green
Safety devices
Compressor overheat protection, Overcurrent protection,
  Frost protection, Serial signal error protection, Indoor fan motor error protection, 
 Heating overload protection (High pressure control), Cooling overload protection
Installation
  data
Refrigerant piping size (O.D)
mm
Liquid line :
φ6.35 (1/4")   Gas line :φ12.7 (1/2")
Connecting method
Flare connecting
Attached length of piping
m
Liquid line : 0.53
   Gas line : 0.40
Insulation for piping
Necessary (Both sides), independent
Refrigerant line (one way) length
m
Max. 25
Vertical height difference between
outdoor unit and indoor unit
Max. 15 (Outdoor unit is higher)
Max. 15 (Outdoor unit is lower) 
Drain hose
Connectable (VP16)
Power cable
Recommended breaker size
A
16
Connection wiring
Size x Core number
1.5mm
2
 x 4 cores (Including earth cable)
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit, Clean filter (Allergen clear filter x 1, Photocatalytic washable deodorizing filter x 1)
Optional parts
Interface kit (SC-BIKN-E)
Note (1) The data are measured at the following conditions.
Item
Operation
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
DB
WB
Cooling
27˚C
19˚C
35˚C
24˚C
ISO-T1, JIS C 9612
Heating
20˚C
7˚C
6˚C
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220/230/240V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.
     (Purging is not required even for the short piping.)
The pipe length is 7.5m.
Adapted to 
RoHS directive