PROBLEM P
OSSIBLE CAUSE 
REMARK 
Air filter 
Clean or replace if restricted. 
Vent door 
Close if open. 
Unit undersized 
Determine if the unit is properly sized for 
the area to be cooled or heated. 
Condenser and Evaporator 
Clean if restricted. 
Fan motor 
Check the fan capacitor and replace if not 
within +/-10% of manufacturer’s rating. 
Room structure 
Take proper measures to make sure doors 
and windows are sealed well. 
Air flow 
Clean or remove if any barrier is found to 
block the inlet/outlet wind flow of the unit 
(drapes, shrubs, etc.). 
Sunlight 
Add a awning if the unit is exposed to direct 
sunlight or move the unit to another window 
that’s not exposed to direct sunlight. 
Refrigerant loss 
Check the tubes for leakage. Reclaim the 
refrigerant, correct the leakage points and 
recharge. 
Capillary tube 
Regulate the flow of capillary tube and 
ensure the evaporating temperature is 
appropriate, if the evaporator is frosted. 
Replace if blocked. Repair joint if leaking. 
Compressor 
The inlet and outlet valve of the 
compressor may be damaged, making the 
low pressure connected with the high 
pressure. The refrigerating system can not 
produce high pressure and low pressure. 
Replace the compressor after checking for 
the reason of failure. 
Heat sources 
Reduce if too many (dryers, electric 
heaters, small appliances, etc.) 
Insufficient cooling 
or heating. 
Drainage 
If drainage is blocked it will increase the 
efficiency in cooling mode, but will cause 
the condenser to frost in heating mode. 
Remove any obstacles. 
Refrigerant 
If the amount of the refrigerant is too large, 
making the compressor load too large. 
Reclaim and recharge the refrigerant after 
checking for the reason of failure. 
Stop instantly after 
startup. 
Compressor 
The compressor is seized. Replace after 
checking for the reason of failure. 
 
 