Panasonic CS-XE9EKE User Manual

Page of 20
7
ENGLISH
AUTO FILTER CLEANING
Auto Filter Cleaning
AUTO
AUTO
•  Filter cleaning will run automatically after the air conditioner operation stops (air conditioner is turned 
off using remote control).
•   After the filter cleaning is completed, the air conditioner operation will remain off.
AIR CONDITIONER TIMER
AIR CONDITIONER TIMER
•  Filter cleaning will run automatically after the air conditioner operation stops (air conditioner is turned 
off by the air conditioner timer).
•  After the filter cleaning is completed, the air conditioner operation will remain off.
Filter Cleaning Indicator
FORCE CLEANING
FORCE CLEANING
•  Once the air conditioner operation time exceeds 24 hours, the unit is forced to run filter cleaning.
•  After the filter cleaning is completed, the air conditioner operation will resume automatically.
• The fi lter cleaning indicator light 
will move to left or right when fi lter 
cleaning is in progress.
•  Filter cleaning in progress will be 
cancelled if:
  -  Certain button on the remote 
control are pressed.
  -  The air conditioner main unit’s 
movable front panel is lifted up.
  -  There is a power failure.
Troubleshooting
●  Timer indicator is blinking and error code H51 is 
revealed on the display.
► The fi lter cleaning device is jammed because the fi lter is not installed 
correctly.
► The fi lter cleaning device is malfunction.
●  Timer indicator is blinking and error code H52 is 
revealed on the display.
► The fi lter cleaning device is malfunction.
►  Printed circuit board is malfunction.
Note : 
•  To reveal the error code, please refer to Product Overview’s troubleshooting-error code checking.
•  The condition above does not affect the unit’s operation.
•  In case of malfunction, please consult your nearest authorized dealer.
■ 
About
Filter cleaning