Sanyo SAP-CRV123EH User Manual

Page of 77
10
Outdoor Unit
SAP– CRV123EH
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Fan & Fan Motor
Type … Fan / Fan Motor
Propeller / DC Motor
Q’ty … Dia.
mm
1 … 370
Fan motor model … Q’ty
DAJ12-55J71-C … 1
No. of poles … Rough measure rpm (Cool / Heat)
8 … 750 / 750
Nominal output
W
50
Coil resistance (Ambient temp. 20°C)
Ω


Safety devices
Type
Operating temp.
Open
°C
Close
°C
Run capacitor on control PCB (A)
µF
VAC
Heat Exchanger Coil
Coil
Aluminum plate fin / Copper tube
Rows
2
Fin pitch
mm
1.4
Face area
m
2
0.367
External Finish
Acrylic baked-on enamel finish
Control PCB (A) / Control PCB (B)
Part No.
CB-CRV123EH (POW-CRV123GJH)
Controls
Microprocessor
Control circuit fuse
250V, 20A
Compressor
Type
DC Rotary (Hermetic)
Compressor model / Nominal output
G4C090LU1ER / 600W
Compressor oil … Amount
cc
FV50S … 320
Coil resistance (Ambient temp. 20°C)
Ω
U – V: 0.81
V – W: 0.81
W – U: 0.81
Safety devices
CT (Peak current cut-off control)
YES
Compressor discharge temp. control
YES
Operation cut-off control in abnormal ambient temp.
Run capacitor
µF
VAC
Crankcase heater