Sanyo SAP-CRV123EH User Manual

Page of 77
23
6.  ELECTRICAL DATA
6-1.  Electrical Characteristics
Indoor Unit
SAP-KRV93EH
Outdoor Unit SAP-CRV93EH
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230V Single-phase 50Hz
Rating conditions
Running amp.
A
0.17
Power input
kW
0.033
0.21
0.048
Rating conditions:
Indoor air temperature:         27
°
C D.B. / 19
°
C W.B.
Outdoor air temperature:      35
°
C D.B. 
Rating conditions:
Indoor air temperature
20
°
C D.B. 
Outdoor air temperature
7
°
C D.B. / 6
°
C W.B.
Heating
Cooling
3.48
0.674
3.86
0.755
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230V Single-phase 50Hz
Rating conditions
Running amp.
A
0.17
Power input
kW
0.035
0.21
0.048
4.43
0.912
4.81
0.995
Indoor Unit
SAP-KRV123EH
Outdoor Unit SAP-CRV123EH
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230V Single-phase 50Hz
Rating conditions
Running amp.
A
0.17
Power input
kW
0.035
0.14
0.030
Rating conditions:
Indoor air temperature:         27
°
C D.B. / 19
°
C W.B.
Outdoor air temperature:      35
°
C D.B. 
Rating conditions:
Indoor air temperature:         20
°
C D.B. 
Outdoor air temperature:      7
°
C D.B. / 6
°
C W.B.
Heating
Cooling
4.90
1.025
5.21
1.090
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230V Single-phase 50Hz
Rating conditions
Running amp.
A
0.17
Power input
kW
0.035
0.14
0.030
5.17
1.100
5.48
1.165