Sanyo SAP-CRV123EH User Manual

Page of 77
5
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
Rating conditions are:
Cooling: Indoor air temperature
27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Heating: Indoor air temperature
20°C D.B.
Outdoor air temperature 7°C D.B. / 6°C W.B.
2.  SPECIFICATIONS
2-1.  Unit Specifications
Indoor Unit
SAP-KRV93EH
Outdoor Unit
SAP-CRV93EH
Power Source
220 – 240V Single-phase 50Hz
Performance
Cooling
Heating
Capacity
kW
2.65 (0.9 – 3.2)
3.60 (0.9 – 5.0)
BTU/h
9,000 (3,100 – 10,900)
12,300 (3,100 – 17,100)
Air circulation (High)
m
3
/h
480
530
Moisture removal (High)
Liters/h
1.6
Electrical Rating
Cooling
Heating
Available voltage range
V
198 – 264
Running amperes
A
3.86 (1.28 – 5.88)
4.81 (1.21 – 6.47)
Power input
W
755 (250 – 1,150)
995 (250 – 1,340)
Power factor
%
85
90
C.O.P.
W/W
3.51
3.62
Compressor locked rotor amperes
A
15
Features
Controls / Temperature control
Microprocessor / I.C. thermister
Control unit
Wireless remote control unit
Timer
ON / OFF 24 hours & Daily program, 1-hour OFF
Fan speeds
Indoor / Outdoor
3 and Auto / 1 (Hi)
Airflow direction (Indoor)
Horizontal
Manual
Vertical
Auto
Air filter
Washable, Anti-Mold
Compressor
Rotary (DC inverter)
Refrigerant / Amount charged at shipment
g
R410A / 950
Refrigerant control
Electric expansion valve
Operation sound
Indoor: Hi / Me / Lo
dB-A
34 / 31 / 28
34 / 31 / 28
Outdoor: Hi
dB-A
46
47
Refrigerant tubing connections
Flare type
Max allowable tubing length at shipment
m
7.5
Refrigerant
Narrow tube
mm (in.)
6.35 (1/4)
tube diameter
Wide tube
mm (in.)
9.52 (3/8)
Refrigerant tube kit / Accessories
Optional / Air clean filter
Voltage Rating
230V
Dimensions & Weight
Indoor Unit
Outdoor Unit
Unit dimensions
Height
mm
285
548
Width
mm
825
720
Depth
mm
189
265
Package dimensions
Height
mm
350
600
Width
mm
900
856
Depth
mm
255
362
Weight
Net
kg
9.0
34.0
Shipping
kg
11.0
36.0
Shipping volume
m
3
0.080
0.186