Installation
1. Using  template  provided,  determine  mounting
location.
2.Drill  holes  and  attach  mounting  hardware  (not
included).
IMPORTANT:
THE HARDWARE AND THE
SUPPORTING STRUCTURE MUST BE CAPABLE OF
SUPPORTING A MINIMUM 150 LB. LOAD.
NOTE: All installation should be done to meet local
building code
.
3. Mount cabinet on wall and securely tighten hardware.
4.Replace  motor/blower  assembly  in  cabinet.  Secure
two  wing  nuts  on  blower  base.  Reconnect  motor
electric cord plug assembly and heater plug.
5.Replace  intake  grille  with  louvers  facing  down  and
refasten knurled nuts.
FIELD POWER WIRING
WARNING:
ALL AIR CURTAINS SHOULD BE
INSTALLED BY QUALIFIED PERSONNEL.
1.Before wiring, be sure that available power supply, 
voltage, phase, and frequency corresponds to that 
specified on heater rating plate.  In addition, make cer-
tain that service capacity is sufficient to handle load 
imposed by the equipment.
2.Install  all  wiring,  protection  and  grounding  in  accor-
dance  with  the  National  Electrical  Code  (NEC)  and
all local requirements.
WARNING: THIS FAN HAS AN INTERNAL SELF
RESETTING THERMAL  OVERLOAD  PROTECTOR.
ALWAYS DISCONNECT FROM POWER SUPPLY
BEFORE SERVICING.
3.Remove  two  screws  from  switch  box  and  remove
cover.
4. Run proper size copper power supply conductors from
the  field  power  supply  disconnects,  (supplied  by
others) with insulation rated minimum 75˚C (167.0˚F).
One set of conductors from 240VAC, 50/60Hz supply
source  shall  be  routed  through  the  3/4  inch  conduit
knockout, using a suitable knockout connected to the
contactor  contact  terminals  marked  L1,  L2.    A
separated  set  of  supply  conductors  from  a  120VAC,
50/60  Hz  supply  source  shall  be  routed  through  1/2
inch knockout using a suitable knockout connector, for
connection  of  the  fan  circuit.    The  fan  supply
conductors  are  to  be  marked  L1,  N  (see  diagram  on
inside heater wiring compartment cover and Figure 5).
5.The  heater  control  box  must  have  an  unbroken
electrical  ground  to  minimize  personal  injury  if  an
electrical fault should occur.
FIELD CONTROL WIRING
Electric heater is equipped with a step-down transformer
for 24V control circuit.  Thermostat model number RSV-
130-R-54 must be used to energize heater with the fan
motor.    Connect  thermostat  wiring  from  thermostat  to
control leads in heated air curtain control box by means
of conduit or equivalent.  A 1/2 inch knockout is provided.
Class1 wiring is required.
6. Replace heater control box cover.
7. Unit is ready for operation.
8. Restore power.
NOTE: Air curtain has high/low selector switch. See
Operation section for proper setting instructions.
9.  Upon  completion  of  all  installation,  inspect  unit  for
excessive  vibration  during  operation.  If  excessive
vibration  is  noticeable,  disconnect  power  supply.
Inspect 
mounting 
installation 
and 
refer 
to
Troubleshooting Chart for probable cause.
Figure 5 - Wiring Diagram