10. Assure that all seams on the vent side of the combustion 
systems are air tight. Apply a high temperature (+500°F) 
sealing compound where needed (Dow Corning, Silastic 
736, Loctite Superflex 596 or equivalent).
The restrictor plate must also be sealed to furnace tube 
sheet.
SECURE OWNERS APPROVAL
When the system is functioning properly, secure the owner’s
approval. Show him the location of all disconnect switches
and the room temperature sensors. Teach him how to start
and stop the unit and how to adjust the temperature settings
within the limitations of the system.
FIGURE 48 - TYPICAL FLUE BAFFLE
"A"
"A"
OUTLET TUBES
FLUE BAFFLE
NOTE: 
 One end of each flue baffle is provided
    with a sharper bend than the other end - this
    sharper bend must be positioned at the tube and 
    attached with a stainless steel screw.
REMOVE
SCREWS