For the best cooling performance and highest energy efficiency
Keep the filter clean
Make  sure  that  your  air  conditioner  is  always  in  top 
performing condition by cleaning the filter regularly. 
In struc tions for removing and cleaning the filter can be 
found on page 7.
Provide good air flow
Make sure the airflow to and from the unit is clear. Your 
air conditioner puts the conditioned air out at the top of the 
unit, and takes in unconditioned air at the bottom. Airflow 
is critical to good operation. It is just as important on the 
outside of the build ing that the airflow around the unit 
exterior is not blocked.
Unit placement
If your air conditioner can be placed in a window or wall 
that is shaded by a tree or an oth er building, the unit will 
operate  even  more  efficiently.  Using  drapes  or  blinds  on 
the sunny side of the dwelling will also add to your unit’s 
efficiency.
Insulation
Good insulation will be a big help in maintaining desirable 
comfort levels. Doors should have weather stripping. Be 
sure to caulk around doors and windows. 
Proper installation of seal gasket
Make sure the seal gasket has been installed properly to 
minimize noise and improve effi ciency. If the seal gasket 
has  not  been  installed,  please  refer  to  your  installation 
instruction manual.
MODEL
CIRCUIT RATING OR 
TIME DELAY FUSE
PLUG FACE
AMP
VOLT
N° NEMA
SS08 • SS09 • SS10 • SS12 • SS14
15
125
5-15P
SS12 • SS16 • SM18 • SM21
15
250
6-15P
Test the power cord
All Friedrich room air conditioners are shipped from the 
factory with a Leakage Current Detection Interrupter 
(LCDI) equipped power cord. The LCDI device meets 
the UL and NEC requirements for cord connected air 
conditioners effective August 2004.
To test your power supply cord:
1.  Plug  power  supply  cord  into  a  grounded  3  prong 
outlet.
2.  Press RESET (See Figure 2).
3.  Press TEST (listen for click; Reset button trips and 
pops out).
4.   Press and release RESET (listen for click; Reset button 
latches and remains in). The power supply cord is ready 
for operation.
Figure 1
Figure 2
TEST
RESET
Test Button
Reset Button
NOTE: LCDI device is not intended to be used as a 
switch.
Once plugged in the unit will operate normally without the 
need to reset the LCDI device. 
If the device fails to trip when tested or if the power supply cord 
is damaged it must be replaced with a new supply cord from 
the manufacturer. We recommend you contact our Technical 
Assistance Line
  at  (800)  541-6645  ext.  662.  To  expedite 
service, please have your model and serial number available.