Friedrich CP15F10A User Manual

Page of 20
B
C
C
A
D
Power supply 
cord
Wiring requirements
115-volt (103.5 min. - 126.5 max.)
0-12 amps
15-amp time-delay fuse or circuit breaker
Use on single outlet circuit only.
230-volt (207 min. - 253 max.)
0-12 amps
15-amp time-delay fuse or circuit breaker
Use on single outlet circuit only.
¹⁄₄"
(0.6 cm)
The wall opening measurements should be:
Height (A): 17 ¼" plus twice thickness of wood used to build 
frame
Width (B): 26 ¼"
Depth (D): 4" minimum to 8" maximum.
Electrical Requirements
Ground wire must be connected to ground screw located in lower 
right corner of air conditioner when air conditioner is in cabinet.
The electrical ratings for your air conditioner are listed on the 
model and serial number (nameplate) label. The model and serial 
number label is located behind the front panel on the flange below 
the control panel area. 
Specific electrical requirements are listed in the chart below. 
Follow the requirements for the type of plug on the power supply 
cord.
Window installation 
Window opening measurements:
27"min. to 42" max. (76.2 cm to 101.6 cm) opening width (A).
20" min. (50.8 cm) opening height (B).
Through-the-wall installation
A.27"   min.  (76.2 c m)
B . 20" min. (50.8 c m)
A
B
A. 17 ¼" 
B. 26 ¼"
C. Wood thickness
D. 4" minimum to 
8" maximum. 
CP1
5
CP18 / CP24
4